6.7.2.11 F14/F15: Start control (time/current) adjustment
Set the time and current for start control to be performed at the time of welding start.
Depending on the welding conditions and set current value, the appropriate time and current for start
control are determined; if proper burning of the wire does not occur at the time of start, adjust the time
and current for start control.
For more intense burning, increase the time and current.
For less intense burning, reduce the time and current.
• Set the time from -50 to 50 % through F14 (Start control time adjustment).
• Set the current in the range from -100 to 100 A through F15 (Start control current adjustment).
6.7.2.12 F16: Slowdown speed adjustment
Slow-down speed is the speed to slowly feed the wire from the time of the machine start to the time of
arc start.
The slowdown speed is automatically set to an appropriate speed depending on the welding method and
wire diameter; meanwhile, it can be adjusted through this function if manual setting is preferred.
The setting range is ±39 IPM (±1.0 m/min), yet cannot be adjusted slower than 16 IPM (0.4 m/min).
Based on "0," adjusting it to the negative direction lowers the speed, and adjusting it to the positive
direction accelerates the speed.
When the starting performance is poor, decrease the slow-down speed to a negative value (which lowers
the wire feed speed).
When the starting performance is not poor, setting the slow-down speed to a positive value (which
accelerates the wire feed speed) can shorten the tact time.
6.7.2.13 F17/F18: Anti-stick time/voltage adjustment
Set the anti-stick time/voltage, which is the anti-stick processing time and voltage. Optimum setting of
the anti-stick time/voltage enables to obtain the following effects:
• At the welding completion, wire adhesion to the base material can be prevented.
• The shape of wire tip can be arranged to obtain a stable start of the next welding.
The time and voltage for anti-stick process are automatically set to appropriate conditions depending on
the welding method (wire type) and wire diameter; meanwhile, it can be adjusted through this function
if wire should cause adhesion at the end of welding or if burning is too intense.
• Adjust the anti-stick process time in the range of ±50 (unit: 0.01 seconds) through the internal function F17.
Based on "0," adjusting it to the negative direction shortens the time, and adjusting it to the positive
extends the time.
Time
Current
Turbo start current
Start current
Summary of Contents for OTC WB-P400
Page 2: ......
Page 8: ...TABLE OF CONTENTS vi MEMO...
Page 52: ...WIRING OF VOLTAGE DETECTION CABLE AT BASE METAL SIDE CONNECTION CHAPTER 4 4 18...
Page 112: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 50...
Page 130: ...CHECKING SOFTWARE VERSION ADMINISTRATOR FUNCTIONS CHAPTER 7 7 18...
Page 142: ...TROUBLESHOOTING TROUBLESHOOTING CHAPTER 9 9 6...
Page 158: ...MATERIALS FOR SETTING WELDING CONDITIONS REFERENCE MATERIALS CHAPTER 10 10 16...