C
ONNECTION
OF
E
XTERNAL
E
QUIPMENT
C
ONNECTION
C
HAPTER
4
4-12
4.5.2
Connection of automatic machine
This section explains the procedure for connection of automatic machine with the welding power source.
4.5.2.1
Wiring for connecting automatic machine
The welding power source is equipped with terminal block for external connection inside the cover for
external connection at the rear. When connecting to the automatic machine, use this terminal block for
external connection.
Terminal No.
Signal name
Function
TM1
1-2
A
Output for
ammeter
Output terminal to connect a separately sold Ammeter
(600 A / 60 mV)
Part No. :4403-054
TM2
1-2
V
Output for
voltmeter
Output terminal to connect a separately sold Voltmeter
(100 V F.S.)
Part No. : 4401-019
TM3
1-2
READY
Power ready
output
When the welding power source side is ready to start welding, the
contact between the terminals closes.
When an error is detected, the contact opens.
3-4
STOP
Operation stop
input
Disconnecting the terminals stops output of the welding power
source.
When combining switches, use a push-lock, turn-reset switch for
preventing accidental reset.
5-9
IN-EXT1
External input 1 Reserve inputs for expanding terminal functions.
Setting the internal functions (Function) allows you to externally
open and close the gas valve and perform inching operation.
(
6.7
-
Setting Internal Functions)
6-9
IN-EXT2
External input 2
7-9
IN-EXT3
External input 3
8-9
IN-EXT4
External input 4
TM4
1-2
24 V 0.2 A
24 V power
source
Outputs power supply of 24 V.
Current capacity: 0.2 A (Maximum)
3-4
OUT EXT1
External output
1
Extra outputs for expanding functions
Setting the internal functions (Function) allows you to output the
signal of the welding condition error.
(
6.7.2.20
-
F25 to F28: External output terminal setting)
5-6
OUT EXT2
External output
2
7-8
OUT EXT3
External output
3
9-10
OUT EXT4
External output
4
11-12
WCR
WCR output
When welding current is detected, the contact between the
terminals closes.
•
Input signal of the external connection terminal block
Use switches and relays with contact capacity of 24 V/10 mA or
more for connecting with the input terminal.
25/64 to 7/16"
25/64 to 7/16" (10 to 11 mm)
Approx. 5 mA
GND
DC24 V
Contact capacity
24 V/10 mA or more
Welding power
source side
㩷
Summary of Contents for OTC WB-P400
Page 2: ......
Page 8: ...TABLE OF CONTENTS vi MEMO...
Page 52: ...WIRING OF VOLTAGE DETECTION CABLE AT BASE METAL SIDE CONNECTION CHAPTER 4 4 18...
Page 112: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 50...
Page 130: ...CHECKING SOFTWARE VERSION ADMINISTRATOR FUNCTIONS CHAPTER 7 7 18...
Page 142: ...TROUBLESHOOTING TROUBLESHOOTING CHAPTER 9 9 6...
Page 158: ...MATERIALS FOR SETTING WELDING CONDITIONS REFERENCE MATERIALS CHAPTER 10 10 16...