6-5
Chapter 6
W
elding Condition
L
IST
OF
W
ELDING
C
ONDITIONS
W
ELDING
C
ONDITION
C
HAPTER
6
F55
Arc loss detection time
OFF (fixed)
OFF
Used when connecting with OTC automatic
machine.
-
F56
Arc start error
detection time
F57
WCR output ON
delay time
F58
WCR output OFF
delay time
F59
Analog setting switch
F60
Pulse peak current fine
adjustment
-150 to 150
0 (A)
Sets the adjustment value of pulse peak current
in pulse welding.
○
F61
Pulse peak time fine
adjustment
-1.5 to 1.5
0.0 (ms)
Sets the adjustment value of pulse peak time in
pulse welding.
○
F62
Base current fine
adjustment
-60 to 60
0 (A)
Sets the adjustment value of base current in pulse
welding.
○
F63
L pulse peak current fine
adjustment
-150 to 150
0 (A)
Sets the adjustment value of pulse peak current
at the LOW side in pulse welding.
○
F64
L pulse peak time fine
adjustment
-1.5 to 1.5
0.0 (ms)
Sets the adjustment value of pulse peak time at
the LOW side in pulse welding.
○
F65
L-base current fine
adjustment
-60 to 60
0 (A)
Sets the adjustment value of base current at the
LOW side in pulse welding.
○
F66
Feeding amplitude ratio
adjustment
0 to 100
50 (%)
Sets the feeding amplitude ratio of wire feeder
speed in wave pulse welding.
○
F67
Setting change of current
value (initial condition, crater
condition)
OFF/ON
OFF
When “CRATER ON” is selected, sets the current
value of the initial condition and crater condition
in the percentage based on the current value of
the welding condition.
OFF: invalid
ON: settable with percentage
-
F68
Setting of current value
(initial condition)
10 to 300
100 (%)
Sets the current value of the initial condition in the
percentage based on the current value of the
welding condition.
-
F69
Setting of current value
(crater condition)
10 to 300
100 (%)
Sets the current value of the crater condition in
the percentage based on the current value of the
welding condition.
-
F77
Welding result control
function identification
numbers
1 to 999
1
Sets welding power source identification numbers
of Welding result control function.
-
F79
Switching of CAN
communication connection
device
0/1
0
Sets the connection device to be used for the CAN
communication.
(available when "0/1/2" is selected in F4)
0: The devices other than "1"
1: Digital panel (E-2628) and LCD panel (E-2627)
-
F80
Switching of CAN
communication speed
0/1/2/3
0
Sets the communication speed of the CAN
connection.
(available when "0/1/2" is selected in F4)
Set to “0” to use the Digital panel (E-2628) and
LCD panel (E-2627).
0: 500 kbps
1: 1 Mbps
2: 125 kbps
3: 250 kbps
-
No.
Function Name
Setting range
Initial value
Explanation
Memory
Summary of Contents for OTC WB-P400
Page 2: ......
Page 8: ...TABLE OF CONTENTS vi MEMO...
Page 52: ...WIRING OF VOLTAGE DETECTION CABLE AT BASE METAL SIDE CONNECTION CHAPTER 4 4 18...
Page 112: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 50...
Page 130: ...CHECKING SOFTWARE VERSION ADMINISTRATOR FUNCTIONS CHAPTER 7 7 18...
Page 142: ...TROUBLESHOOTING TROUBLESHOOTING CHAPTER 9 9 6...
Page 158: ...MATERIALS FOR SETTING WELDING CONDITIONS REFERENCE MATERIALS CHAPTER 10 10 16...