L
IST
OF
W
ELDING
C
ONDITIONS
W
ELDING
C
ONDITION
C
HAPTER
6
6-4
F45
Special crater
sequence
OFF/ON
OFF
Sets the initial condition and crater condition as
applied for a fixed period of time regardless of the
torch switch operation:
OFF: Not applied
ON: Applied (Time set by F46 and F47 is applied)
○
F46
Special crater sequence
initial time
0.0 to 10.0
0.0 (s)
Sets initial time in the special crater sequence.
(available when "ON" is selected in F45)
○
F47
Special crater sequence
crater time
0.0 to 10.0
0.0 (s)
Sets crater time in the special crater sequence.
(available when F45 is enabled)
○
F48
Adjusting current with torch
switch
OFF/ON
OFF
With the setting of "Crater" and in the welding
condition (during start input holding), sets
whether to adjust current by the torch switch
operation:
OFF: not to use torch switch
ON: uses torch switch (increase/decrease
volume set by F49 and F50 are applied).
○
F49
Current increase and
decrease by single-clicking
-50 to 50
0 (A)
Sets current increase/decrease volume by single
clicking of the torch switch. (available when "ON"
is selected in F48)
○
F50
Current increase and
decrease by double-clicking
-50 to 50
0 (A)
Sets current increase/decrease volume by double
clicking of the torch switch. (available when "ON"
is selected in F48)
○
F51
Special crater repeat
OFF/ON
OFF
With the setting of "Crater," sets whether to switch
the welding condition and crater condition by the
click operation of the torch switch:
OFF: not to use torch switch
ON: uses the torch switch
○
F52
Data type of data log
function
0 to 8
0
Sets sample data on the data log:
0: No sampling
1: Welding current / Welding voltage / Sequence
information
2: Current command / Voltage command /
Feeding command
3: Current command / Welding current / Welding
voltage
4: Current command / Welding current /
Sequence information
5: Welding current / Voltage command / Welding
voltage
6: Voltage command / Welding voltage /
Sequence information
7: Welding current / Feeding command /
Sequence information
8: Welding voltage / Feeding command /
Sequence information
-
F53
Sampling speed of data log
function
1/2/3
1
Sets sampling interval of the data log function:
1: 10 ms
2: 100 ms
3: 1 s
-
F54
Tack start process
OFF/ON
OFF
Sets whether to feed the wire with the slowdown
speed at the time of welding start:
OFF: Feeds with slow down speed
ON: Feeds without slow down speed
-
No.
Function Name
Setting range
Initial value
Explanation
Memory
Summary of Contents for OTC WB-P400
Page 2: ......
Page 8: ...TABLE OF CONTENTS vi MEMO...
Page 52: ...WIRING OF VOLTAGE DETECTION CABLE AT BASE METAL SIDE CONNECTION CHAPTER 4 4 18...
Page 112: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 50...
Page 130: ...CHECKING SOFTWARE VERSION ADMINISTRATOR FUNCTIONS CHAPTER 7 7 18...
Page 142: ...TROUBLESHOOTING TROUBLESHOOTING CHAPTER 9 9 6...
Page 158: ...MATERIALS FOR SETTING WELDING CONDITIONS REFERENCE MATERIALS CHAPTER 10 10 16...