Use the voltage detection cable for torch side (K5416P00) with a blind bush.
4.
Remove the voltage detection cable (line No. 309) connected to the bracket.
5.
Restore the plates in the right side and left side of the wire feeder.
Wiring for the wire feeder is complete.
4.5.2
Connection of automatic machine
This section explains the procedure for connection of automatic machine with the welding power source. LCD panel robot
version kit is required to change the welding power source from manual mode to automatic mode. (
control, voltage detection cable and other optional items)
4.5.2.1
Wiring for connecting automatic machine
The welding power source is equipped with terminal block for external connection inside the cover for external connection
at the rear. When connecting to the automatic machine, use this terminal block for external connection.
Terminal No.
Signal name
Function
TM1
1-2
A
Output for
ammeter
Output terminal to connect a separately sold Ammeter
(600 A / 60 mV)
Part No.: 4403-054
TM2
1-2
V
Output for
voltmeter
Output terminal to connect a separately sold Voltmeter
(100 V F.S.)
Part No.: 4401-019
TM3
1-2
READY
Power ready
output
When the welding power source side is ready to start welding, the contact
between the terminals closes.
When an error is detected, the contact opens.
3-4
STOP
Operation stop
input
Disconnecting the terminals stops output of the welding power source.
When combining switches, use a push-lock, turn-reset switch for
preventing accidental reset.
5-9
IN-EXT1
External input 1
Reserve inputs for expanding terminal functions.
Setting the internal functions (Function) allows you to externally open and
close the gas valve and perform inching operation. (
6-9
IN-EXT2
External input 2
7-9
IN-EXT3
External input 3
8-9
IN-EXT4
External input 4
TM4
1-2
24 V 0.2 A
24 V power source
Outputs power supply of 24 V.
Current capacity: 0.2 A (Maximum)
3-4
OUT EXT1
External output 1 Extra outputs for expanding functions
Setting the internal functions (Function), allows you to output the signal of
the welding condition error.
(
F25 to F28: External output terminal setting)
5-6
OUT EXT2
External output 2
7-8
OUT EXT3
External output 3
9-10
OUT EXT4
External output 4
11-12
WCR
WCR output
When welding current is detected, the contact between the terminals
closes.
•
Input signal of the external connection terminal block
Use switches and relays with contact capacity of 24 V/10 mA or more for
connecting with the input terminal.
Approx. 5 mA
GND
DC24 V
Contact capacity
24 V/10 mA or more
Welding power
㻌
source side
㻌
Summary of Contents for OTC ARXIS pulse P403L
Page 1: ...July 2023 Manual No P30433 1 DAIHEN Corporation ARXIS pulse P403L P503L OWNER S MANUAL...
Page 174: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 172 10 2 1 Schematic diagram ARXIS WB P403L...
Page 175: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 173 Chapter 10 Reference Materials...
Page 176: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 174 ARXIS WB P503L...
Page 177: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 175 Chapter 10 Reference Materials...