L
IST
OF
W
ELDING
JOB
W
ELDING
C
ONDITION
C
HAPTER
6
67
Chapter 6
W
elding Condition
F64
L pulse peak time fine
adjustment
-1.5 to 1.5
0.0 (ms)
Sets the adjustment value of pulse peak time at the
LOW side in pulse welding.
○
F65
L-base current fine adjustment
-60 to 60
0 (A)
Sets the adjustment value of base current at the LOW
side in pulse welding.
○
F66
Feeding amplitude ratio
adjustment
0 to 100
50 (%)
Sets the feeding amplitude ratio of wire feeder speed in
wave pulse welding.
○
F67
Setting change of current value
(start condition, crater
condition)
OFF/ON
OFF
When "4T" is selected, sets the current value of the start
condition and crater condition in the percentage based
on the current value of the welding condition.
OFF: invalid
ON: settable with percentage
○
F68
Setting of current value (start
condition)
10 to 300
100 (%)
Sets the current value of the start condition in the
percentage based on the current value of the welding
condition.
○
F69
Setting of current value (crater
condition)
10 to 300
100 (%)
Sets the current value of the crater condition in the
percentage based on the current value of the welding
condition.
○
F70
Upper limit setting for analog
remote control
20 to 400 (*1)
400 (A)
Sets the upper limit (the value when the knob is turned
clockwise all the way) of the welding current adjustable
by the analog remote control (optional accessory).
-
20 to 550 (*2)
550 (A)
F71
Interval function
OFF/ON
OFF
This function repeats arc ON/OFF to control the heat
input.
○
F72
Interval function Arc ON time
0.20 to 9.99
1.00 (s)
Sets the Arc-ON time in the Interval function.
○
F73
Interval function Arc OFF time
0.20 to 9.99
1.00 (s)
Sets the Arc-OFF time in the Interval function.
○
F74
No function
OFF (fixed)
OFF
No functions are provided.
-
F75
Wire inching initial speed
0 / 0.4 to 2.0
0.4 (m/min) Sets the inching speed for the first second.
-
F76
Wire feeder select
OFF / ON
ON
Allows to select the wire feeder to use.
OFF: CM-7403
ON: CM-0401-D
-
F77
Welding power source
identification numbers
1 to 999
1
Sets whether power source identification numbers of
Welding result control function.
-
F78
Prevention of unintended torch
switch operation
OFF/ON
OFF
An error code is displayed when welding is not
performed for five seconds after the pre-flow.
-
F79
Switching of CAN
communication connection
device
0/1/2/3
1
Sets the connection device to be used for the CAN
communication.
0: Digital Remote Control Box
1: Digital panel (Attached to wire feeder) and Intelli
torch
2: Digital pull torch
3: Digital middle feeder
-
F80
Switching of CAN
communication speed
0/1/2/3
0
Sets the connection speed of the CAN connection.
0: 500 kbps
1: 1 Mbps
2: 125 kbps
3: 250 kbps
-
F81
Torch switch setting with TIG
mode
OFF/ON
OFF
During TIG MODE, operating the torch switch can control
the welding start and end.
-
F82
Arc stabilization for DC pulse
welding
0 to 30
0
If DC pulse welding is unstable by using extended power
supply cable, set to larger value side with the longer
extended cable for arc stabilization.
-
F83
Adjustment of Arc length after
arc start
-20 to 10
0
Adjusts the arc length right after starting the welding
operation.
-
F84
Automatic pulse adjustment
0/1/2
0
Sets the pulse mode that has the pulse automatic
adjustment function.
0: Standard pulse mode
1: Pulse mode for automatic adjustment
2: Pulse mode for automatic adjustment; Fixing of
adjustment value
○
F85
Adjustment amount in
automatic pulse adjustment
-9.99 to 9.99
0
The currently retained adjustment amount of pulse
automatic adjustment can be checked. In addition, the
adjustment amount can be changed manually.
○
No.
Function Name
Setting range
Initial value
Explanation
Memory
Summary of Contents for OTC ARXIS pulse P403L
Page 1: ...July 2023 Manual No P30433 1 DAIHEN Corporation ARXIS pulse P403L P503L OWNER S MANUAL...
Page 174: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 172 10 2 1 Schematic diagram ARXIS WB P403L...
Page 175: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 173 Chapter 10 Reference Materials...
Page 176: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 174 ARXIS WB P503L...
Page 177: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 175 Chapter 10 Reference Materials...