6.7.2.26 F36/F37: Spatter adjustment (P1P/P2P)
Use this function to manually set the detection sensitivity of [Squeeze]. This function is available when the internal
function F34 (Automatic correction of [Squeeze] detection sensitivity) is set to [OFF].
Follow the step below for setting the adjustment.
1.
Set the internal function F34 (Automatic correction of low spatter function) to OFF.
2.
Display the internal function F36 (Spatter adjustment (P1P)), and carry out the welding with F36 displayed.
3.
Increase or decrease the setting value of internal function F36, and carry out the welding again.
●
Repeat this step until the good condition of welding is obtained, by adjusting the set value in the range of -100 to
100.
4.
Display the internal function F37 (Spatter adjustment (P2P)), and carry out the welding with F37 displayed.
5.
Increase or decrease the setting value of internal function F37, and carry out the welding again.
●
As in the step 3, repeat the step until good condition is obtained, by adjusting the set value in the range of -100 to
100.
6.7.2.27 F38: Arc voltage detection switching
Sets the combination of enabling or disabling the voltage direct detection terminal on the base metal side of the welding
power source and voltage detection terminal of the wire feeder.
Extending the power cable without the cable at the base metal side can cause extraordinary volume of spatter. In this case,
setting this function to "1" by using the voltage detection cable (optionally available) can improve the status.
Connection of voltage detection cable (
-
Wiring of Voltage Detection Cable at Base Metal Side)
•
[0]: Direct detecting (Wire feeder)
Terminal detecting (Base metal)
•
[1]: Direct detecting (Wire feeder)
Direct detecting (Base metal)
•
[2]: Terminal detecting (Wire feeder)
Terminal detecting (Base metal)
T I P S
•
Use the voltage detection cable (optionally available) when the total length of the extension
cable is 30 m or longer.
•
When using wire feeder CM-7403, water-cooled welding torch cannot be used. Accordingly,
arc voltage direct detection switch cannot be activated even with this function set to "1".
•
When using a reverse-polarity wire, set this function to "2".
•
When the welding process is "DC", you can set this function to "2".
– Then, the welding process "DC(EN)" will be displayed on the HOME screen.
– “Reading out of welding JOB” in F2, F29 to 32, F44 can be read only for the welding JOB
whose welding process is "DC".
– The welding process cannot be changed to other than "DC" with this function to "2". Be
sure to set to "0" or "1" to change to other welding process.
Summary of Contents for OTC ARXIS pulse P403L
Page 1: ...July 2023 Manual No P30433 1 DAIHEN Corporation ARXIS pulse P403L P503L OWNER S MANUAL...
Page 174: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 172 10 2 1 Schematic diagram ARXIS WB P403L...
Page 175: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 173 Chapter 10 Reference Materials...
Page 176: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 174 ARXIS WB P503L...
Page 177: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 175 Chapter 10 Reference Materials...