W
ELDING
R
ESULT
C
ONTROL
F
UNCTION
A
DMINISTRATOR
F
UNCTIONS
C
HAPTER
7
140
Example: The settings when the set value of welding current is 200 A and that of welding voltage is 20 V.
•
ERROR judgment time
Select the time to judge the event as an error in the range from 0 to 100 seconds when the average current/ voltage
(average per second) during welding is out of the allowable tolerance range.
When the out-of-range state becomes longer than the time specified here, an alarm displays. (
-
indication at the time of ERROR detection)
If "0" is set, ERROR detection will not be performed.
7.3.2.5
Total operating time
Total operation time is managed according to the display range.
•
Cumulative total operation time
The operation time of welding power source is counted at all time and accumulated as total operation time. The setting
range of count value is between 0 hr: 0 min to 16 hr: 39 min.
7.3.2.6
Alarm indication when target is achieved
When any of the number of welding points, wire consumption and total welding time reaches the target specified, the
notification will appear on the touch panel.
•
The display returns to the normal state when any item or key of the operation panel is selected.
•
If continuous operation is enabled in the setting of the operation for the time when the target is achieved, an alarm
will display every time welding finishes until any item or key of the operation panel is selected.
<Example> When Welding points reached the target value
Current tolerance (+) is set to "10" % (= 220 A)
Current tolerance (-) is set to "20" % (= 160 A)
Voltage tolerance (+) is set to "20" % (= 24 V)
Voltage tolerance (-) is set to "10" % (= 18 V)
In the example above, the allowable tolerance range of welding current is 160 to 220 A and that of welding voltage is 18 to 24 V.
Summary of Contents for OTC ARXIS pulse P403L
Page 1: ...July 2023 Manual No P30433 1 DAIHEN Corporation ARXIS pulse P403L P503L OWNER S MANUAL...
Page 174: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 172 10 2 1 Schematic diagram ARXIS WB P403L...
Page 175: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 173 Chapter 10 Reference Materials...
Page 176: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 174 ARXIS WB P503L...
Page 177: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 175 Chapter 10 Reference Materials...