Alarm Control Panel Installer Manual
50
Submenu
Setting
TROU AL MODE
Trouble alarm response mode.
Set the TROUBLE ALARM (PSTN disconnection, GSM failure, antenna
tamper, AC loss, battery loss, battery voltage failure, SIM expiration, time
display problem) response type: SILENT, BUZZER, SIREN, and BUZ/SIR.
COM TRO ALM
COM trouble alarm.
Set the COM trouble (interruption to the connection) response type:
SILENT, BUZZER, SIREN, and BUZ/SIR.
BAT TRO ARM
Arming with battery trouble.
Set whether the presence of low battery condition (in the control panel or a
wireless sensor) allow to arm the system.
YES
NO
ARM DLY AL
Set whether the use of alarm delay is enabled with the system armed in
total arm mode. In practice, the siren alarm can be delayed by a
programmable period while the keypad displays indicate that alarm has
been triggered.
YES
NO
ENY/EXT BEEP
Entry/Exit sounds with partial arming.
Set whether the sound of keypad buzzers for the entry and exit times is
enabled or disabled during arming of the types Partial 1, Partial 2, or
Partial 1+2.
YES
NO
PANIC AL MOD
Panic alarm mode.
Set whether audible alarm or silent alarm is generated by a Panic event.
AUDIBLE
SILENT
DURESS MOD
Enable or disable duress function. If enabled, you can vary the last digit of
the access code to activate duress alarm (1234 becomes 1235 or 1233).
YES
NO
PWD ERR MAX
Password error maximum.
Set the maximum permitted number of errors in code entry from the
keypad (00 to 10). 00 represents there is no limit. If the maximum entry
time is reached, the current Keypad will be locked for 3 minutes.
FACTORY RST
Set whether the control panel is enabled to restore factory settings.
PART: Delete all control panel data except the wireless devices codes
(such as sensors and sirens)
TOTL: Delete all control panel data.
NO: The reset of factory default procedure will have no effect.
EOL R VALUE
Set the EOL value to 2.7K, 4.7K, or 6.8K. The panel zones termination
supports NC, NO, 1EOL, 2EOL and 3EOL. For 1EOL and 2EOL, the
resistors value can be set to 2.7K, 4.7K, or 6.8K; for 3EOL, the resistors
value is fixed to 2.7K (R1, R2), and 6.8K (R3). See Figure 1-6.
Summary of Contents for DHI-ARC3008C
Page 1: ...Alarm Control Panel Installer Manual V1 0 1 ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD ...
Page 16: ...Alarm Control Panel Installer Manual 15 Wiring of detectors Figure 1 6 ...
Page 17: ...Alarm Control Panel Installer Manual 16 Keypad connection Figure 1 7 ...
Page 67: ...Alarm Control Panel Installer Manual 66 Vocal message flow Figure 1 36 ...