Alarm Control Panel Installer Manual
35
Table 1-13 Wired zone setting
Submenu
Setting
STATE
ACTIVE: This wired zone is fully operational.
ISOLATE: This wired zone is programmed but permanently bypassed
from the system.
TEST: This wired zone is operational but does not generate alarms.
OFF: This wired zone is not used.
TYPE
You can set the zone for the most suitable type for the installation.
INSTANT: The zone reacts to the intrusion immediately without waiting
for any delay period.
ENTRY 1 DELAY: The zone reacts after the delay 1 period is set in the
AREAS menu.
ENTRY 2 DELAY: The zone reacts after the delay 2 period is set in the
AREAS menu.
Path: The zone triggers an immediate alarm if it is the first affected by
an intrusion. However, the delay follows for the Area to which it
belongs. If a delay 1 Zone is the first affected, Path indicates that it is a
Zone will not trigger an immediate alarm.
EXIT END: The EXIT END termination zone is used when you want to
terminate an output countdown before it ends. This is very useful when
it is unable to establish an output path with a fixed period, you can set it
very high then terminate. For example, by closing the door on which a
contact is mounted and programmed as an output terminator, the
terminator can also act as a button. After arming successfully, the
Z
one’s Entry Delay is Entry 1 Delay.
24H: The 24-hour zone is always active regardless of the area to which
it is assigned. This setting is used for anti-opening or high-security
protective measures.
FIRE: The fire zone is used when you also want to install smoke
detector or buttons within the alarm system, If you program in the fire
zone, it will activate the fire alarm and pre-alarm outputs for the area to
which it belongs. The fire alarm period set in the SYSTEM TIMING
menu will then follow and it will never affect intrusion alarms. If it is
programmed with single or double balancing, the tamper will be read
and managed as a FIRE TROUBLE.
PANIC: The panic zone is active for 24 hours a day and generates a
sound or silent alarm depending on the settings input in the SYSTEM
FUNCTIONS menu. Panic outputs are activated for the area to which
the setting is assigned. When a panic zone activates, the display shows
"panic alarm."
ROBBERY: The zone is active for 24 hours a day and generates a
silent alarm. The hold-up outputs are activated for the area to which the
setting is assigned. The LCD display does not show the alarm and no
LED flashes.
MEDICAL: The medical zone is active for 24 hours a day and always
generates a sound alarm by means of a keypad buzzer only. It
Summary of Contents for DHI-ARC3008C
Page 1: ...Alarm Control Panel Installer Manual V1 0 1 ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD ...
Page 16: ...Alarm Control Panel Installer Manual 15 Wiring of detectors Figure 1 6 ...
Page 17: ...Alarm Control Panel Installer Manual 16 Keypad connection Figure 1 7 ...
Page 67: ...Alarm Control Panel Installer Manual 66 Vocal message flow Figure 1 36 ...