Alarm Control Panel Installer Manual
43
Submenu
Setting
ALARM MEMORY: Follows the addition to the memory of a siren
alarm being triggered. It remains active until the User reset.
READY: Follows the zone ready condition. This can be one or more
areas.
PART1 ALARM: Follows an alarm condition due to an intrusion in
Partition 1 (this can be one or more areas). Follows alarm conditions
such as the system siren alarm output, but with alarm times for the
area.
PART2 ALARM: Follows an alarm condition due to an intrusion in
Partition 2 (this can be one or more areas). Follows alarm conditions
such as the system siren alarm output, but with alarm times for the
area.
FIRE: Follows an alarm condition due to the activation of a wire or
radio fire zone (this can be one or more areas).
FIRE TROUBLE: Follows an alarm condition due to the activation of a
fire failure (fire zone tamper).
PANIC: Follows a PANIC alarm condition (this can be one or more
areas).
ROBBERY: Follows a ROBBERY alarm condition (this can be one or
more areas).
MEDICAL: Follows a MEDICAL alarm condition (this can be one or
more areas).
DURESS: Follows a duress condition due to arming or disarming
under duress.
TIMER ERROR: Follows a condition of failure ARM operated by
TIMER.
24H ZONE: Follows an alarm conditions due to the activation of a
24-hour zone (this can be one or more areas).
AREAS
Select the areas (1 to 8) that you want to assign the outputs to.
The areas can be assigned in individual or combined mode.
In the case of multiple areas, the output is connected to them in OR or
AND mode that is defined on the next screen.
To assign or remove Areas from the Keypad, press the corresponding key
(1 to 8) and then press
. The number of the assigned Area appears
on the programming line to confirm that the selection was successful. The
number of the assigned Area disappears from the programming line to
confirm that the deselection was successful.
Summary of Contents for DHI-ARC3008C
Page 1: ...Alarm Control Panel Installer Manual V1 0 1 ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD ...
Page 16: ...Alarm Control Panel Installer Manual 15 Wiring of detectors Figure 1 6 ...
Page 17: ...Alarm Control Panel Installer Manual 16 Keypad connection Figure 1 7 ...
Page 67: ...Alarm Control Panel Installer Manual 66 Vocal message flow Figure 1 36 ...