Alarm Control Panel Installer Manual
18
3 System Boot-Up
Setting Keypad Address
1.8
Every Keypad registered to the Control Panel must have a unique address. When replacing the Keypad,
the new Keypad must use the same address as the previous Keypad.
Before powering on the system, set an address (range: 1
–8) for the Keypad by DIP switches on the
Keypad. The address value beyond the specified range is not acceptable.
The default Keypad address is 1.
The DIP switches 5
–8 are reserved functions and might be developed in the future.
Table 1-4 DIP switch and keypad address
DIP switch
Keypad address
DIP switch
Keypad address
1
2
3
4
5
6
7
8
Booting up the Control Panel
1.9
Power on the Control Panel, and then the Keyboard registration is completed and the system enters into
the normal working conditions within 75 seconds.
Booting up the Keypad
1.10
The Keyboard gets registered to the Control Panel within five seconds after it is powered on. Before
registration, the Area 1
–8 LED indicators glows and LCD display shows the Keyboard version information.
Factory Default Settings
1.11
ZONE is N.O. type by default.