Alarm Control Panel Installer Manual
42
1.26.2 Configuring OUTPUT Categories
On the CATEGORIES submenu, press
or
to select the output category from AREAS, ZONES,
LINK, GENERIC, or SYSTEM, and then press
to enter the programming mode of output that you
selected.
Press
and
to alter the options. Press
to confirm the setting and move to the next
submenu.
By entering the OUTPUTS menu when the LCD display shows the name of output, it is possible to
manually activate the output to test its operation: Press
+ 1 (F1), the ACTIVE interface is shown. See
Figure 1-23.
Active
Figure 1-23
The text ACTIVE is flashing. The output activates and remains activated manually until the
or
is pressed. The TECHNICIAN then can manually test all the system outputs.
AREA Outputs
Table 1-16 Areas outputs programming
Submenu
Setting
TYPE
AREA ON: Follows Area(s) armed status.
AREA OFF: Follows Area(s) armed status.
PART1 ON: Follows Partition 1 armed status.
PART2 ON: Follows Partition 2 armed status.
EXIT TIME: Follows the exit delay time for the assigned area. In the
case of multiple areas, it follows the longest period.
ENTRY TIME: Follows the entry time for the assigned area. In the
case of multiple areas, it follows the longest period.
IN AND OUT DELAY TIME: Follows both the exit time and entry time
for the assigned area.
FORCED ARM: Follows forced arming with unready zones. This
function is useful for notifying that TIMER arming has been provided
with a certain number of NOT READY zones which are therefore
automatically bypass from arming.
CHIME: Follows the CHIME alarm condition in a chime zone (this can
be one or more areas).
ZONE BYPASS: Follows the existence of BYPASSED zones.
ZONE TAMPER: Follows an alarm condition due to the activation of a
wired or wireless zone tamper (this can be one or more areas).
Summary of Contents for DHI-ARC3008C
Page 1: ...Alarm Control Panel Installer Manual V1 0 1 ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD ...
Page 16: ...Alarm Control Panel Installer Manual 15 Wiring of detectors Figure 1 6 ...
Page 17: ...Alarm Control Panel Installer Manual 16 Keypad connection Figure 1 7 ...
Page 67: ...Alarm Control Panel Installer Manual 66 Vocal message flow Figure 1 36 ...