SYSTEM Outputs
The system outputs follow on from general system conditions regardless of the areas.
Table 1-20 System outputs programming
Item
Setting
TYPE
SIREN ALARM: Follows the generic alarm condition and the timing is
in according to SYSTEM FUNCTIONS setting.
SYSTEM TAMPER: Follows Control Panel tamper condition.
SIREN TAMPER: Follows Siren tamper condition.
KEYPAD TAMPER: Follows Keypad tamper condition.
COM1 TROUBLE: Follows a fault condition on the COM1 generated
by the bus modules.
WALK TEST: Follows the placing of the Control Panel in WALK TEST
mode.
TECHNICIAN: Follows the entry of the TECHNICIAN into
programming.
CODE ERROR: This type of output activates when the counter for the
number of false codes entered reaches the parameter set in SYSTEM
FUNCTIONS. The duration of the output activations is 3 minutes.
COM. BUSY: This type of output follows telephone communication in
progress.
TROUBLES: Follows a failure of troubles that include a loss of PSTN
LINE, a loss of GSM telephone line, antenna tamper, main power
supply loss, battery loss, low battery voltage, SIM expiry, time
abnormality.
POLAR
Select the output polarity.
DIRECT
REVERSE
AREAS
1.27
After entering the Installer Menu, press
and
to scroll up and down until you reach the
Step 1
AREAS menu. See Figure 1-24.
Areas
Figure 1-24
Press
to enter the programming mode.
Step 2
Summary of Contents for DHI-ARC3008C
Page 1: ...Alarm Control Panel Installer Manual V1 0 1 ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD ...
Page 16: ...Alarm Control Panel Installer Manual 15 Wiring of detectors Figure 1 6 ...
Page 17: ...Alarm Control Panel Installer Manual 16 Keypad connection Figure 1 7 ...
Page 67: ...Alarm Control Panel Installer Manual 66 Vocal message flow Figure 1 36 ...