125
Parameter
Note
Enable
You need to check the box to enable motion detection function.
Working
Period
It is to set the alarm period, it can enable alarm event only in the set time range.
There are six periods every day for setup and you must check box in front of
each period to enable it.
Select days (Sunday by default, if select all the week, then it means applying
the setup into the whole week; you can also check the box in front of the day
and make setting for some days separately).
Click “OK” button after completing setup, go back to motion detect setting page,
click
“OK” button to finish working period setup of motion detect
Note:
Period setup can be done by dragging mouse while not releasing left mouse.
Anti-dither
System only memorizes one event during the anti-dither period. The value ranges
from 0s to 100s.
Area
Click “Setup” button to enter the interface, you can set the effective area of motion
detect according to the actual situation and set its sensitivity and area threshold
(The higher the sensitivity is, the easier to trigger motion detect; the smaller the
area, the easier to trigger motion detect.) The default covers all regions. You must
click on save before enabling your setup.
Record
Check it and so when alarm occurs, system will auto record.
Note:
Please refer to
“6.1.2.5 Storage path” for storage location query and setting of
recorded file.
When motion detect alarm happens, system record needs to satisfy the
following two conditions:
Motion detect record has been enabled, please refer to
“6.7.1.2 Record
Plan
” for more details.
Auto record has been set, please refer to
“6.7.3 Record Control” for more
details.
Record Delay
System can delay the alarm record for specified time after alarm ended. The value
ranges from 10s to 300s.
Relay out
Connect alarm devices to relay-out port (such as light, alarm whistle and so on), the
system will transmit alarm info to alarm devices when motion detection alarm
happens.
Alarm Delay
System can delay the alarm output for specified time after alarm ended. The value
ranges from 10s to 300s.