PILOT’S OPERATING HANDBOOK
SECTION 3
EMERGENCY PROCEDURES
EASA Approved
Edition 0 -- October 31, 2013
Rev. 1
Page 3.9.6
OXYGEN USE
WARNING
SMOKING IS STRICTLY PROHIBITED ANY TIME OXYGEN SYSTEM IS USED. BEFORE
USING OXYGEN, REMOVE ANY TRACE OF OIL, GREASE, SOAP AND OTHER FATTY
SUBSTANCES (INCLUDING LIPSTICK, MAKE UP, ETC...)
Front seats
1 - Take a mask on the opposite seat side (pilot : R.H. side ; R.H. Front passenger : L.H. side) : draw it out of the
stowage cup and uncoil tube totally. Press on the red side vanes to inflate the harness. Put the mask on the
face.
2 - No smokes :
3-position selector
NORMAL
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(100 % as required)
3 - In case of smokes :
3-position selector
EMERGENCY
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Don the smoke goggles onto the face
4 - ”PASSENGERS OXYGEN” switch
ON
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 - Check the oxygen flow indicator for the front seats (the blinker is transparent) and for the rear passengers
(the blinker is green).
6 - ”MICRO/MASK” micro inverter
MASK
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 - Perform an emergency descent to the ”En route” minimum altitude and, if possible, below 10000 ft.
Passengers
1 - Take a mask.
2 - Uncoil tube totally.
3 - Pull on the lanyard cord to take out the lanyard pin.
4 - Put the mask on the face.