PILOT’S OPERATING HANDBOOK
SECTION 4
NORMAL PROCEDURES
EASA Approved
Edition 0 -- October 31, 2013
Rev. 1
Page 4.4.17
MOTORING (2/2)
To cool engine following shut-down in high temperature environment :
4 - ”STARTER” switch
ON, take a time
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
during 30 sec
WARNING CAS MESSAGE
”STARTER”
ON
. . . . . . . . . . . . . . . . . . . .
If ignition symptoms occur (ITT increasing), check that ”IGNITION” switch is OFF, that throttle is on CUT OFF and
continue motoring.
5 - ”STARTER” switch
ABORT
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARNING CAS MESSAGE
”STARTER”
OFF
. . . . . . . . . . . . . . . . . . .
6 - FUEL panel
-
”AUX BP” switch
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARNING CAS MESSAGE
”AUX BOOST PMP ON”
OFF
. . . . . .
WARNING CAS MESSAGE
”FUEL PRESS”
ON
. . . . . . . . . . . . . . . .