Inspecting the needle valve for full lift
a. Install gasket (026508-1140) and plug
(157892-1600 : SW12mm) onto the
adjusting retaining nut (157892-1400).
b. Install the nozzle holder on the plate
with the cap nut facing upward.
c. Install the holder into the cap nut.
d. Install a nut (157892-1000 : SW 17mm)
on the holder.
e.
Assemble the pin (157892-4200 or
157892-4300) to the dial gauge
(157954-3800).
Note : “L” means the length of the pin
except the threaded portion.
- 111 -
EQM4042I
EQM4045I
Part No.
L (mm)
157892-4200
160
157892-4300
110