![Dacor ER30D Technical Manual Download Page 28](http://html1.mh-extra.com/html/dacor/er30d/er30d_technical-manual_3143192028.webp)
Page 9-13
S
ECTION
9 - C
OMPONENT
R
EPAIR
Crown burner orifice replacement
(continued)
The simmer orifice is attached to a fitting on
the side of the crown burner. Remove the
fitting retaining clip
T
to access the simmer
orifice fitting.
Pull the fitting
U
out of the side of the
burner.
Use a 7 mm hex wrench to remove the
simmer orifice
V
from the fitting.
Tighten the replacement orifice into place with
a 7 mm hex wrench.
Repeat the above steps for the other crown
burner if it requires service.
Venturi Adjustment
For proper operation, the gap between the end of
the crown burner main orifice
R
and the end of
the venturi
X
needs to be set to 9 mm.
To adjust the venturi gap, loosen the
set screw
W
on the side of the venture
assembly.
Slide the venturi in and out of the venturi
assembly to adjust the gap.
After Burner Service is Complete:
Reinstall the spill trays.
Reattach the igniter wires to the stack burner
igniters.
Reassemble the cooktop and test it to ensure
that repairs were properly completed.
•
•
•
•
•
•
•
•
•
•
T
U
V
W
R
X