Cooktop Component Repair (continued)
Regulator
Turn off the gas supply at the supply valve
and power to the range at the junction or fuse
box.
Pull the range out from the wall or cabinet.
Remove the gas regulator access cover
A
from the back of the range
B
.
•
•
•
A
B
Disconnect the gas supply line
C
to the
regulator
D
.
Disconnect the flex tube
E
from the top of
the regulator.
Hold the regulator in one hand while removing
the two (2) screws
F
from the regulator
bracket. Remove the regulator through the
access hole.
Reassemble the regulator in the reverse order.
Turn the gas supply on and check for leaks
using a gas leak detector or bubble forming
fluid.
Turn on the power at the junction or fuse
box. Test the cooktop for proper operation
according the installation instructions.
Turn off the power and gas supply. Reinstall
the gas regulator access cover.
Push the range back into position in the wall
or cabinet.
Turn on gas supply and power. Test the
cooktop to ensure that repairs were properly
completed.
•
•
•
•
•
•
•
•
•