Ensure that the end stops are secure.
Recommended 70mm
Ensure that the wheels are turning freely.
Recommended 80mm wheels
Rollers must roll freely.
The roller mounting can be used as an anti-lift device,
.
In the case of the rollers coming off the mounting, the
gate must remain in an upright position.
A device must be fabricated to allow for this.
If the gate has a full portal, the portal will provide for this
Check the start up force of the gate using a fishing scale.
Ensure that the rail is level.
The gate must not move on its own when left in any position on the rail.
GATE EVALUATION
It is extremely important to evaluate the gate that is to be automated before any automation is done. The following points must be
checked. All of the points mentioned below are common causes of gate problems if not checked.
PULL
Maximum start-up force = 10kg
It is recommended that 16mm round bar is used to assist with the
smooth operation of he gate
The gate must not jam in the catch bracket when opening or
closing as this may cause the motor to over current
Summary of Contents for Compact
Page 12: ......