L.E.D. INDICATIONS
There are several light emitting diodes (L.E.Ds) on the main P.C.Board. These L.E.Ds indicate several conditions. These in-
dications are as follows:-
STAUS LED. ON = gate open or gate is in motion.
OFF = mains power off.
FLASHING ONCE EVERY TWO SECONDS = gate closed and mains power on.
FLASHING 4 TIMES = rev counter fault.
FLASHING 3 TIMES = motor fuse blown or electric motor fault.
OPEN LED. ON = gate open
OFF = gate closed.
CLOSED LED. ON = gate closed.
OFF= gate open.
12v LED. ON = normal.
OFF= 12 volt output fault.
INF LED. ON = normal.
OFF = infra red beams faulty or obstruction in front of beams.
This LED should be on at all times unless there is an obstruction in front of the beams.
TRIG LED. ON = trigger fault.
OFF = normal.
This LED should be off at all times and will flash when the motor is receiving a trigger.
PED LED. ON = trigger fault.
OFF = normal.
This LED should be off at all times and will flash when the motor is receiving a trigger.
CHARGE LED (green LED on the outside of the motor). ON = normal.
OFF = battery is not charging .
LOW BATT LED (red LED on the outside of the motor) ON = battery is flat
OFF = normal