Summary of Contents for 884 mct

Page 1: ...umweltfreundlich 100 Altpapier pour la nature papier recycl 100 for nature recycled paper 100 per la natura carta riciclata 100 para la naturaleza 100 papel reciclado C ERME T A Z I E N D A C E R TIF...

Page 2: ...m s main switch 12 An omnipower switch shall be provided for the installation with an opening distance of the contacts of 3 mm or more Alternatively use a 6A thermomagnetic breaker with multi pole swi...

Page 3: ...iding gate By using a self braking motor the system is guaranteed to be mechanically locked when the motor is not in operation so a lock does not need to be installed The gear motors have adjustable m...

Page 4: ...mount the pinion on the transmission shaft and fit the casing provided as shown in fig 6 4 4 MECHANICAL INSTALLATION 1 Remove the casing 2 fig 2 and position the gear motor on the foundation plate Fi...

Page 5: ...with adequate tripping threshold Connecttheearthcabletotheappropriateseatontheoperator base see fig 20 The operator is equipped with a safety device fig 1 ref 7 activated by the release device If enab...

Page 6: ...5 6 7 8 9 10 11 12 13 14 15 MOTOR LINE FCA FCC LAMP T1 T2 T3 N L1 L2 L3 400V 3ph N R S T M 3Ph 230 V MOTOR LINE T1 T2 T3 N L1 L2 L3 230V 3ph Fig 15 LED A LED OPEN LED B LED OPEN PARTIALLY CLOSE LED S...

Page 7: ...ave no effect during opening If engaged when the gate is open or pausing closing safety devices prevent its closing To install several safety devices connect the N C contacts in series If closing safe...

Page 8: ...GATE STATUS CLOSED OPEN IN PAUSE CLOSING OPENING STOPPED OPEN A OPEN B 1 opens and re closes after pause time 2 re closes after 5 3 reverses motion no effect re closes 2 TABLE 6 LOGIC A2 AUTOMATICA PL...

Page 9: ...further 10 mm and secure it provisionally on the rack by two weld spots 4 Manually take the gate to closing position leave it 5 cm from the limit stop 5 Allow the plate to slide over the rack in clos...

Page 10: ...A safety microswitch in the release system prevents the automation from being activated by accidental commands 7 fig 2 Close the door and open or close the gate manually 8 RETURN TO NORMAL OPERATION O...

Page 11: ...or sliding gates is an electromechanical operator which transmits movement to the leaf by means of a pinion with rack or chain coupled in an appropriate manner to the sliding gate If automatic operati...