background image

12

ENGLISH

ENGLISH

IMPORTANT NOTICE FOR THE INSTALLER

GENERAL SAFETY REGULATIONS

1) WARNING!

 

FAAC strongly recommends to follow these instructions literally for the safety of persons. Improper

installation or misuse of the product will cause very serious damages to persons.

2) Read the instructions carefully before installing the product.

3) Packaging material (plastic, polystyrene etc.) is a potential hazard and must be kept out of reach of children.

4) Keep these instructions for future reference.

5) This product has been designed and manufactured only for the use stated in this manual. Any other use not expressly

set forth will affect the reliability of the product and/or could be source of hazard.

6) FAAC S.p.A. cannot be held responsible for any damage caused by improper use or different from the use for which

the automation system is destined to.

7) Do not use this device in areas subject to explosion: the presence of flammable gas or fumes is a serious hazard.

8) Mechanical constructive elements must comply with UNI8612, EN 12604 and EN 12605 standards. Countries outside

the EC shall follow the regulations above besides their national normative references in order to offer the utmost
safety.

9) FAAC cannot be held responsible for failure to observe technical standards in the construction of gates and doors,

or for any deformation of the gates which may occur during use.

10) Installation must comply with UNI8612, EN 12453 and EN 12445.

11) Before carrying out any operations, turn off the system’s main switch.

12) An omnipower switch shall be provided for the installation with an opening distance of the contacts of 3 mm or more.

Alternatively, use a 6A thermomagnetic breaker with multi-pole switching.

13) Ensure that there is a differential switch up-line of the electrical system, with a trip threshold of 0.03A.

14) Check that the earthing plant is in perfect condition and connect it to the metallic parts. Also earth the yellow/green

wire of the operator.

15) The safety devices (e.g. photocells, safety edges, etc.) protect areas wherethere is a 

mechanical movement

hazard

, e.g. crushing, entrapment and shearing.

16) Each installation must be fitted with at least one flashing light (EN 12978 standard) as well as a warning plate suitably

fixed to the gate, besides the safety devices as per point 15. above.

17) FAAC cannot be held responsible regarding safety and correct functioning of the automation in the event that parts

other than FAAC original parts are used.

18) Use only FAAC original spare parts for maintenance operations.

19) Do not carry out any modifications to automation components.

20) The installer must supply all information regarding manual operation of the system in the event of an emergency

and provide the end-user with the "End-user Guide" attached to the product.

21) Keep out of persons when the product is in operation.

22) Keep out of reach of children the remote radio controls and any control devices. The automation could be

operated unintentionally.

23) The end-user must avoid any attempt to repair or adjust the automation personally. These operations must be

carried out exclusively by qualified personnel.

24) What is not explicitly stated in these instructions is not permitted.

Summary of Contents for 884 mct

Page 1: ...umweltfreundlich 100 Altpapier pour la nature papier recycl 100 for nature recycled paper 100 per la natura carta riciclata 100 para la naturaleza 100 papel reciclado C ERME T A Z I E N D A C E R TIF...

Page 2: ...m s main switch 12 An omnipower switch shall be provided for the installation with an opening distance of the contacts of 3 mm or more Alternatively use a 6A thermomagnetic breaker with multi pole swi...

Page 3: ...iding gate By using a self braking motor the system is guaranteed to be mechanically locked when the motor is not in operation so a lock does not need to be installed The gear motors have adjustable m...

Page 4: ...mount the pinion on the transmission shaft and fit the casing provided as shown in fig 6 4 4 MECHANICAL INSTALLATION 1 Remove the casing 2 fig 2 and position the gear motor on the foundation plate Fi...

Page 5: ...with adequate tripping threshold Connecttheearthcabletotheappropriateseatontheoperator base see fig 20 The operator is equipped with a safety device fig 1 ref 7 activated by the release device If enab...

Page 6: ...5 6 7 8 9 10 11 12 13 14 15 MOTOR LINE FCA FCC LAMP T1 T2 T3 N L1 L2 L3 400V 3ph N R S T M 3Ph 230 V MOTOR LINE T1 T2 T3 N L1 L2 L3 230V 3ph Fig 15 LED A LED OPEN LED B LED OPEN PARTIALLY CLOSE LED S...

Page 7: ...ave no effect during opening If engaged when the gate is open or pausing closing safety devices prevent its closing To install several safety devices connect the N C contacts in series If closing safe...

Page 8: ...GATE STATUS CLOSED OPEN IN PAUSE CLOSING OPENING STOPPED OPEN A OPEN B 1 opens and re closes after pause time 2 re closes after 5 3 reverses motion no effect re closes 2 TABLE 6 LOGIC A2 AUTOMATICA PL...

Page 9: ...further 10 mm and secure it provisionally on the rack by two weld spots 4 Manually take the gate to closing position leave it 5 cm from the limit stop 5 Allow the plate to slide over the rack in clos...

Page 10: ...A safety microswitch in the release system prevents the automation from being activated by accidental commands 7 fig 2 Close the door and open or close the gate manually 8 RETURN TO NORMAL OPERATION O...

Page 11: ...or sliding gates is an electromechanical operator which transmits movement to the leaf by means of a pinion with rack or chain coupled in an appropriate manner to the sliding gate If automatic operati...