background image

20

ENGLISH

ENGLISH

Fig. 23

Fig. 24

Fig. 25

AUTOMATIC

MANUAL

6.

TESTING THE AUTOMATION

When installation is complete, affix the danger warning label to
the top of the casing (Fig. 23). Thoroughly check operation of
the automation and all connected accessories.

7.

MANUAL OPERATION

If the gate has to be operated manually due to a power failure
or malfunction of the automation, use the release device as
follows.

- Open the door in the casing using the triangular key provided

(see fig. 24).

- Operate the relase lever shown in fig. 25 (pos. MANUAL).
- A safety microswitch in the release system prevents the

automation from being activated by accidental commands
(7, fig. 2).

- Close the door and open or close the gate manually.

8.

RETURN TO NORMAL OPERATION

- Open the door in the casing using the triangular key provided

(see fig. 24).

- Move back the lever  shown  in fig. 25 up to the mechanical

stop (pos. AUTOMATIC).

- Close the door.

9.

MAINTENANCE

When performing maintenance always check that the anti-
crushing clutch is correctly regulated and that the safety
devices operate correctly.

10. REPAIRS

For repairs contact an authorised FAAC Repair Centre.

Give the customer the User's Guide.Explain correct use and
operation of the gear motor and draw attention to the potential
danger zones of the automation.

Summary of Contents for 884 mct

Page 1: ...umweltfreundlich 100 Altpapier pour la nature papier recycl 100 for nature recycled paper 100 per la natura carta riciclata 100 para la naturaleza 100 papel reciclado C ERME T A Z I E N D A C E R TIF...

Page 2: ...m s main switch 12 An omnipower switch shall be provided for the installation with an opening distance of the contacts of 3 mm or more Alternatively use a 6A thermomagnetic breaker with multi pole swi...

Page 3: ...iding gate By using a self braking motor the system is guaranteed to be mechanically locked when the motor is not in operation so a lock does not need to be installed The gear motors have adjustable m...

Page 4: ...mount the pinion on the transmission shaft and fit the casing provided as shown in fig 6 4 4 MECHANICAL INSTALLATION 1 Remove the casing 2 fig 2 and position the gear motor on the foundation plate Fi...

Page 5: ...with adequate tripping threshold Connecttheearthcabletotheappropriateseatontheoperator base see fig 20 The operator is equipped with a safety device fig 1 ref 7 activated by the release device If enab...

Page 6: ...5 6 7 8 9 10 11 12 13 14 15 MOTOR LINE FCA FCC LAMP T1 T2 T3 N L1 L2 L3 400V 3ph N R S T M 3Ph 230 V MOTOR LINE T1 T2 T3 N L1 L2 L3 230V 3ph Fig 15 LED A LED OPEN LED B LED OPEN PARTIALLY CLOSE LED S...

Page 7: ...ave no effect during opening If engaged when the gate is open or pausing closing safety devices prevent its closing To install several safety devices connect the N C contacts in series If closing safe...

Page 8: ...GATE STATUS CLOSED OPEN IN PAUSE CLOSING OPENING STOPPED OPEN A OPEN B 1 opens and re closes after pause time 2 re closes after 5 3 reverses motion no effect re closes 2 TABLE 6 LOGIC A2 AUTOMATICA PL...

Page 9: ...further 10 mm and secure it provisionally on the rack by two weld spots 4 Manually take the gate to closing position leave it 5 cm from the limit stop 5 Allow the plate to slide over the rack in clos...

Page 10: ...A safety microswitch in the release system prevents the automation from being activated by accidental commands 7 fig 2 Close the door and open or close the gate manually 8 RETURN TO NORMAL OPERATION O...

Page 11: ...or sliding gates is an electromechanical operator which transmits movement to the leaf by means of a pinion with rack or chain coupled in an appropriate manner to the sliding gate If automatic operati...

Reviews: