![D-Link xStack DGS-3120-48PC Reference Manual Download Page 541](http://html.mh-extra.com/html/d-link/xstack-dgs-3120-48pc/xstack-dgs-3120-48pc_reference-manual_76212541.webp)
xStack
®
DGS-3120 Series Managed Switch CLI Reference Guide
537
<temperature -500-500>
- Enter the high threshold temperature here.
low
- (Optional) To configure low threshold value. n is the low threshold value.
<temperature -500-500>
- Enter the low threshold temperature here.
Restrictions
Only Administrator and Operator-level users can issue this command.
Example
To configure the warning temperature threshold:
DGS-3120-24TC:admin# config temperature threshold high 80
Command: config temperature threshold high 80
Success.
DGS-3120-24TC:admin#
54-4
config temperature
Description
This command is used to configure the trap state for temperature warning event.
Format
config temperature [trap | log] state [enable | disable]
Parameters
trap state
- Specify the trap state for the warning temperature event.
enable
- Enable trap state for warning temperature event. The default state is enabled.
disable
- Disable trap state for warning temperature event.
log state
- Specify the log state for the warning temperature event.
enable
- Enable log state for warning temperature event. The default state is enabled.
disable
- Disable log state for warning temperature event.
Restrictions
Only Administrator and Operator-level users can issue this command.
Example
To configure the warning temperature threshold:
DGS-3120-24TC:admin# config temperature threshold high 80
Command: config temperature threshold high 80
Success.
DGS-3120-24TC:admin#