xStack
®
DGS-3120 Series Managed Switch CLI Reference Guide
185
<centisecond 250-1000>
- Enter the alarm time value here. This value must be between 250
and 1000 centiseconds.
alarm_reset_time
- (Optional) This is the dormant duration time before a defect is triggered
before the fault can be re-alarmed. The unit is centisecond, the range is 250-1000. The default
value is 1000.
<centisecond 250-1000>
- Enter the alarm reset time value here. This value must be
between 250 and 1000 centiseconds.
Restrictions
Only Administrator, Operator and Power-User level users can issue this command.
Example
To configure a CFM MEP:
DGS-3120-24TC:admin# config cfm mep mepname mep1 state enable ccm enable
Command: config cfm mep mepname mep1 state enable ccm enable
Success.
DGS-3120-24TC:admin#
19-7
delete cfm mep
Description
This command is used to delete a previously created MEP.
Format
delete cfm mep [mepname <string 32> | mepid <int 1-8191> md [<string 22> | md_index
<uint 1-4294967295>] ma [<string 22> | ma_index <uint 1-4294967295>]]
Parameters
mepname
- Specify the MEP name.
<string 32>
- Enter the MEP name used here. This name can be up to 32 characters long.
mepid
- Specify the MEP ID.
<int 1-8191>
- Enter the MEP ID used here. This value must be between 1 and 8191.
md
- Specify the maintenance domain name.
<string 22>
- Enter the maintenance domain name used here. This name can be up to 22
characters long.
md_index
- Specify the maintenance domain index.
<uint 1-4294967295>
- Enter the maintenance domain index value here. This value
must be between 1 and 4294967295.
ma
- Specify the maintenance association name.
<string 22>
- Enter the maintenance association name used here. This name can be up to
22 characters long.
ma_index
- Specify the maintenance association index.
<uint 1-4294967295>
- Enter the maintenance association index value here. This value
must be between 1 and 4294967295.