![D-Link xStack DGS-3120-48PC Reference Manual Download Page 225](http://html.mh-extra.com/html/d-link/xstack-dgs-3120-48pc/xstack-dgs-3120-48pc_reference-manual_76212225.webp)
xStack
®
DGS-3120 Series Managed Switch CLI Reference Guide
221
Chapter 22
Debug Software Command
List
debug error_log
[dump | clear | upload_toTFTP <ipaddr> <path_filename 64>]
debug buffer
[utilization | dump | clear | upload_toTFTP <ipaddr> <path_filename 64>]
debug output
[module <module_list> | all] [buffer | console]
debug config error_reboot
[enable | disable]
debug config state
[enable | disable]
debug show jwac auth_info
debug dhcpv6_client state enable
(EI Mode Only)
debug dhcpv6_client state disable
(EI Mode Only)
debug dhcpv6_client output
[buffer | console]
(EI Mode Only)
debug dhcpv6_client packet
[all | receiving | sending] state [enable | disable]
(EI Mode Only)
debug dhcpv6_relay state enable
(EI Mode Only)
debug dhcpv6_relay state disable
(EI Mode Only)
debug dhcpv6_relay output
[buffer | console]
(EI Mode Only)
debug dhcpv6_relay packet
[all | receiving | sending] state [enable | disable]
(EI Mode Only)
debug dhcpv6_relay hop_count state
[enable | disable]
(EI Mode Only)
22-1
debug error_log
Description
This command is used to dump, clear or upload the software error log to a TFTP server.
Format
debug error_log [dump | clear | upload_toTFTP <ipaddr> <path_filename 64>]
Parameters
dump
- Display the debug message of the debug log.
clear
- Clear the debug log.
upload_toTFTP
- Upload the debug log to a TFTP server specified by IP address.
<ipaddr>
- Specify the IPv4 address of the TFTP server.
<path_filename 64>
- The pathname specifies the DOS pathname on the TFTP server. It can
be a relative pathname or an absolute pathname. This value can be up to 64 characters
long.
Restrictions
Only Administrator-level users can issue this command.
Example
To dump the error log: