D-Link DWS-1008 CLI Manual
10
security {unsecured |
Specifies the security level, and is applicable only when
authenticated | encrypted}
applicable only when the SNMP version is usm:
•
unsecured—Message exchanges are not
authenticated, nor are they encrypted.
This is the default.
•
authenticated—Message exchanges are authenticated,
but are not encrypted.
•
encrypted—Message exchanges are authenticated
and encrypted.
SNMPv2c with Informs
To configure a notification target for informs from SNMPv2c, use the following command:
Syntax: set snmp notify target
target-num ip-addr
[
:udp-port-number
] v2c
community-string
inform [profile
profile-name
] [retries
num
] [timeout
num
]
target-num
ID for the target. This ID is local to the switch and does not need to
correspond to a value on the target itself. You can specify a number
from 1 to 10.
ip-addr[:udp-port-number]
IP address of the server. You also can specify the UDP port number
to send notifications to.
community-string
Community string.
profile
profile-name
Notification profile this SNMP user will use to specify the notification
types to send or drop.
retries
num
Specifies the number of times the MSS SNMP engine will resend a
notification that has not been acknowledged by the target. You
can specify from 0 to 3 retries.
timeout
num
Specifies the number of seconds MSS waits for acknowledgement
of a notification. You can specify from 1 to 5 seconds.
SNMPv2c with Traps
To configure a notification target for traps from SNMPv2c, use the following command:
Syntax: set snmp notify target
target-num ip-addr
[
:udp-port-number
]
v2c
community-string
trap [profile
profile-name
]