xStack® DGS-3120 Series Managed Switch Web UI Reference Guide
328
cleared
Multicast storm occurrence
Port <[unitID:]portNum> Multicast storm is
occurring
Warning
Multicast storm cleared
Port <[unitID:]portNum> Multicast storm has
cleared
Informational
Port shut down due to a packet
storm
Port <[unitID:]portNum> is currently shut
down due to a packet storm
Warning
Loopback
Dection
Port loop occurred
Port <[unitID:]portNum> LBD loop occurred.
Port blocked
Critical
Port loop detection restarted
after interval time
Port <[unitID:]portNum> LBD port recovered.
Loop detection restarted
Informational
Port with VID loop occurred
Port <[unitID:]portNum> VID <vlanID> LBD
loop occurred. Packet discard begun
Critical
Port with VID Loop detection
restarted after interval time
Port <[unitID:]portNum> VID <vlanID> LBD
recovered. Loop detection restarted
Informational
The number of VLANs that loop
back has occurred hit the
specified number.
Loop VLAN number overflow
Informational
Gratuitous
ARP
Gratuitous ARP detected
duplicate IP.
Conflict IP was detected with this device (IP:
<ipaddr>, MAC: <macaddr>, Port
<[unitID:]portNum>, Interface: <ipif_name>).
Warning
DHCP
Detect untrusted DHCP server
IP address
Detected untrusted DHCP server(IP: <ipaddr>,
Port: <[unitID:]portNum>)
Informational
DHCP Server
Screening
BPDU
Protection
BPDU attack happened
Port <[UnitID:]portNum> enter BPDU under
attacking state (mode: drop / block /
shutdown)
Informational
BPDU attack automatically
recover
Port <[UnitID:]portNum> recover from BPDU
under attacking state automatically
Informational
BPDU attack manually recover
Port <[UnitID:]portNum> recover from BPDU
under attacking state manually
Informational
Monitor
Temperature exceeds
confidence level
[Uint <unitID>] Temperature Sensor
<sensorID> enter alarm state. (current
temperature: <temperature>)
Warning
Temperature recovers to
normal.
[Uint <unitID>] Temperature Sensor
<sensorID> recovers to normal state. (current
temperature: <temperature>)
Informational
CFM
Cross-connect is detected
CFM cross-connect. VLAN:<vlanid>, Local(MD
Level:<mdlevel>, Port <[unitID:]portNum>,
Direction:<mepdirection>)
Remote(MEPID:<mepid>, MAC:<macaddr>)
Critical
Error CFM CCM packet is
detected
CFM error ccm. MD Level:<mdlevel>,
VLAN:<vlanid>, Local(Port
<[unitID:]portNum>, Direction:<mepdirection>)
Remote(MEPID:<mepid>, MAC:<macaddr>)
Warning
Can not receive remote MEP's
CCM packet
CFM remote down. MD Level:<mdlevel>,
VLAN:<vlanid>, Local(Port
<[unitID:]portNum>, Direction:<mepdirection>)
Warning
Remote MEP's MAC reports an
error status
CFM remote MAC error. MD Level:<mdlevel>,
VLAN:<vlanid>, Local(Port
<[unitID:]portNum>, Direction:<mepdirection>)
Warning
Remote MEP detects CFM
defects
CFM remote detects a defect. MD
Level:<mdlevel>, VLAN:<vlanid>, Local(Port
<[unitID:]portNum>, Direction:<mepdirection>)
Informational
CFM
Extension
AIS condition detected
AIS condition detected. MD Level:<mdlevel>,
VLAN:<vlanid>, Local(Port
<[unitID:]portNum>, Direction:<mepdirection>,
MEPID:<mepid>)
Notice
AIS condition cleared
AIS condition cleared. MD Level:<mdlevel>,
VLAN:<vlanid>, Local(Port
<[unitID:]portNum>, Direction:<mepdirection>,
MEPID:<mepid>)
Notice
LCK condition detected
LCK condition detected. MD Level:<mdlevel>,
VLAN:<vlanid>, Local(Port
<[unitID:]portNum>, Direction:<mepdirection>,
MEPID:<mepid>)
Notice
LCK condition cleared
LCK condition cleared. MD Level:<mdlevel>,
VLAN:<vlanid>, Local(Port
<[unitID:]portNum>, Direction:<mepdirection>,
MEPID:<mepid>)
Notice
Summary of Contents for DGS-3120-24PC-EI