3.3 Configuring Solar BLE Sensor
In this section, you will configure a parameter of the Solar BLE Sensor according to preprogrammed firmware for this kit. You
will do so using a serial USB connection from your PC to send configuration commands to the Solar BLE Sensor.
3.3.1 Connect Solar BLE Sensor to PC
1. Open the enclosure of Solar BLE Sensor using the sharp end of something like tweezers (not included in the kit), and
take out the Solar BLE Sensor Board. Refer to
B.2 How to Install the Board in the Enclosure
in the enclosure.
2. Set the slide switch (SW3) on the Debug Board to the EZ-BLE side. Refer to section
Slide Switch for Target Device
for detailed information on each mode.
3. Connect the Solar BLE Sensor to CN1 of the Debug Board.
4. Plug the Debug Board with the Solar BLE Sensor into your computer
’s USB port. A supercapacitor (SC1) on the Solar
BLE Sensor is charged when the Solar BLE Sensor is connected to the Debug Board via USB. Refer to
SW3
PRoC BLE
EZ-BLE