17
The “Delay(ms)” setting is the length of time to wait before sending
the next command and is set in milliseconds. The interface for
sending commands can be set to the Keypad itself (SysCMD), to
pre-defined Ethernet devices (Device), to a specified IP address
using the Telnet or UDP protocols, or to the relay port (Relay).
Sending commands to devices on the local network, or across the
Internet requires the IP address and network port number of the
destination device. Once the destination information is complete
please click on “Save Changes”.
Note: It is strongly suggested to not set a delay time less than 100ms
for system commands or less than 500ms for Telnet commands to
ensure that the command is properly received and executed before
the next command is sent.
■
Remove Command:
Clicking on the delete icon ( ) will remove
that command from the execution list.
■
Execution Condition:
Use the dropdowns to set a specific
condition for each step in the macro to execute or not. If an
execution condition tests as “false” when it is time to execute that
command, then that step of the macro will be skipped. Selecting
“None” means the macro command will always be executed.