![CXR CIP-2ALL User Manual Download Page 6](http://html1.mh-extra.com/html/cxr/cip-2all/cip-2all_user-manual_2701290006.webp)
User manual
CIP-ALL
CIP-ALL
- Page 6
Restarting the product is not required when changing analog port parameters.
In the Bundle Menu: create a number 3 bundle, set the remote equipment IP address, and tick the relevant analog port number.
Then activate the Bundle and save it. The other parameters satisfy most applications to get started.
Then you must restart the equipment. (See the next chapter).
The Bundle menu shows the IP address previously defined in the general configuration menu.
Note that this IP address may have no relation with the product management IP address.
The default Bundle id number created is 1003 (with Bundle number 3)
In the Reboot (restart) menu: restart the product to activate the Bundle. After reboot, the link is established between the analog ports and the
modems.
Note: depending on the network jitter, some amount of time (seconds to minutes) may be required for perfect recovered clock stability.
The Status / Bundles menu shows the Bundles status and transmission statistics.
When the Bundles are set on both products, this menu shows the Bundle connection status and the real time number of Ethernet / IP packet
transmission.
These counters are refreshed every 10 seconds.