3. 

Front panel and light indicators 

 

The LED indicators are installed on the front panel of the CIP-ALL to show its operation status. 

 

 

 
Admin console port: 

Indicator 

Function 

 / POWER 

Shows that the equipment is powered on. Flashes when the unit is starting, or during a firmware upgrade. 

SYNC 

OFF when all Bundles are synchronized. 

Flashing when a test is in progress. 

ON when a Bundle connection fails 

 
 
It is possible to connect the ADMIN port to the serial port of a computer (19200, 8, N, 1). This connection is not required for the operation of the 
equipment. It is temporary only during installation and testing. 

 

 

 

Term Port: 

Indicator 

Function 

Tx 

Indicates that the user equipment transmits data to the serial port TERM. 

Rx 

Indicates that the user equipment receives data from the serial port TERM. 

 

 

 

 

There are two green LEDs per Ethernet LAN port, and one for the Gigabit Ethernet optical ports: 

Indicator 

Function 

FO1, FO2, 

LINK/ACT (RJ45 right led) 

ON when the port is connected. 

Flashing when Ethernet frames are transmitted through the port. 

100 (RJ45 left led) 

ON when port is connected at 100 Mbit/s. 

OFF when port is connected at 10 Mbit/s (or disconnected if the LINK LED is OFF). 

 
 
E1 Port in option: 

Indicator 

Function 

LOS 

ON when port is disconnected. Available with Unframed and Framed mode. 

OFF when E1 is synchronized. 

AIS 

ON when the E1 port receives an AIS signal. Available with Unframed mode only. 

OFF when the E1 port receives normal data. 

Summary of Contents for CIP-2ALL

Page 1: ...CIP ALL User s Manual P N 8000 602 811 Revision 21 CXR Rue de l Ornette 28410 Abondant France 33 237 628 790 support cxr fr http www cxr com...

Page 2: ...n chapters The team at CXR thanks you for choosing the CIP ALL We hope that this equipment will provide full satisfaction and in order to serve you even better invite you to read the last part of this...

Page 3: ...ter to an Ethernet port for setting up the product Web Interface The factory default IP address is 192 168 1 1 Configure the Computer IP address 192 168 1 11 and netmask 255 255 255 0 Connect the CIP...

Page 4: ...n the Analog Port Menu set the analog interface parameters For example 2 wire mode and internal clock source for one unit and Clock Recovery mode for the other unit Set the clock source Bundle number...

Page 5: ...User manual CIP ALL CIP ALL Page 5...

Page 6: ...this IP address may have no relation with the product management IP address The default Bundle id number created is 1003 with Bundle number 3 In the Reboot restart menu restart the product to activate...

Page 7: ...User manual CIP ALL CIP ALL Page 7...

Page 8: ...ameters 31 5 3 12 Terminal server Serial Port 32 5 3 13 System status 34 5 3 14 E1 status 34 5 3 15 Ports LAN status 35 5 3 16 Bundles Status 35 5 3 17 STP status 36 5 3 18 Switch MAC Table 37 5 3 19...

Page 9: ...telephone set modem fax product Impedance 600 Ohms Maximum Input 0 dB 2 4EM 2 or 4 E M Ear Mouth analog E M interfaces E M input E M SB SG type 1 2 3 4 5 Power 48 Vdc 5 C1 only ET 1 E1 interface RJ45...

Page 10: ...easy access In order to comply with the safety regulations it is imperative to use only the accessories cables provided with the equipment When access to the inside of the modem is necessary it is im...

Page 11: ...ment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users...

Page 12: ...net switch that delivers wire speed switching QoS VLAN functions 1 2 Analog Interfaces The CIP ALL is connected with one or many other remote CIP ALLs to transport 2 or 4 analog interfaces 2 and 4 wir...

Page 13: ...mounting bracket option This manual on the CXR manual CD Connections Connect the equipment as follows front view of the product with E1 port option For safety reasons it is imperative to use the acce...

Page 14: ...esting Term Port Indicator Function Tx Indicates that the user equipment transmits data to the serial port TERM Rx Indicates that the user equipment receives data from the serial port TERM There are t...

Page 15: ...r must be connected to the first LAN port of the CIP ALL The CIP ALL default IP address is 192 168 1 1 CIP ALL configuration can be made in the web interface menus The use of the web interface offers...

Page 16: ...nfig network and answer questions If the choice in parentheses is correct then just press the Enter key If not then enter the proper parameters Welcome to the CIP ALL SN 1110999991003 Enter h to read...

Page 17: ...s Status to get operation status System to perform maintenance operations The top line shows the product name which depends on the installed analog ports and options CIP 4ALL CIP 2ALL 2O for example T...

Page 18: ...TP mode is used when using the Loopback clock and when both product clocks are extracted from a common GPS source or E1 operator network For example Differential used with two external reference clock...

Page 19: ...ly E M CAS Standard on hook off hook and ringing signals are transmitted in the ABCD CAS signaling bits of an E1 frame The number of frames per Ethernet packets is limited to 16 in this mode i e 16x12...

Page 20: ...rver port In this proprietary signaling mode this defines IP protocol port number to send the signaling associated with the IP address of the CIP defined in the Administration Menu LAN IP Address 5 3...

Page 21: ...protocol Next Hop IP This is the IP gateway specifically for this Bundle It may be used if the remote equipment is not in the same IP network which requires a routing process This address must be con...

Page 22: ...N tag is use and 1 or 2 tags are inserted No 802 1Q single VLAN tag stacked VLAN 802 1ad and Q in Q 2x VLAN tags 802 1Q frame DA SA 0x8100 VID1 802 1ad frame Q in Q DA SA Tag VLAN provider Tag 0x8100...

Page 23: ...120 Ohms impedance Unbalanced BNC 75 to use the BNC connectors at standard 75 Ohms impedance CRC4 Yes enable the detection of the CRC4 bits for the framed transmitted on the E1 link No disable the de...

Page 24: ...mode you can choose the TimeSlot assignment and the number of frames in the Payload In this example the time Slots 5 and 6 are chosen and will be transmitted on the remote CIP via TDM In SAToP mode al...

Page 25: ...IP header for traffic priority It has four priority transmit queues per Ethernet port Scheduling The CIP ALL controls four priority levels and two scheduling algorithms to serve the transmit queues S...

Page 26: ...Q DSCP Tagged not IPv4 or IPv6 X Non tagged IPv4 or IPv6 X Other than IP or tagged X Note a DSCP priority value must be set to CPU for the proper operation of the RS232 serial port server DSCP Choose...

Page 27: ...Protocol is specified in the IEEE 802 1D 2004 standard Enable The RING is enabled if this parameter is ON RING or redundant topologies are possible This parameter can be disabled in simple topologies...

Page 28: ...so the traffic passes through the higher rate interfaces Range 0 Auto to 9999 Default 0 Cost_rstp RSTP This parameter defines the cost of each port The Auto value allocates a cost according to the int...

Page 29: ...n can be useful for access untagged ports Discard Ingress Untagged Discard ingress Untagged frames This option can be useful for trunk tagged ports Example with different VLAN ID number for ingress fr...

Page 30: ...the product http https ssh ftp snmp and RS 232 terminal server Http server Enable or disable the HTTP protocol Product configuration may not be changed if this protocol is disabled FTP server Enable...

Page 31: ...e community name for primary and secondary manager Trap LAN Terminal Server Bundles Enable or disable different traps by interfaces Read Community Set the read only community name used to read setting...

Page 32: ...er the next reboot of the CIP ALL 5 3 12 Terminal server Serial Port This menu defines the settings of the asynchronous serial port and the ip parameters for transporting serial data over the network...

Page 33: ...adcast address the frame is transmitted to all slaves defined in the master s table whatever the frame content o Modbus Mode RTU or ASCII defines the address format RTU one binary byte ASCII 3 ascii c...

Page 34: ...ent alarms LOS Loss of Signal when the E1 port has a loss of signal This alarm is available for unframed or framed configuration Check the cable connection to the E1 link connector LOF Loss of Frame a...

Page 35: ...P address of remote IPC is displayed on top of this menu Then the reference clock status is presented The product operation may be described by these statuses Off when the remote system is not connect...

Page 36: ...r example if we define two bundles to the same analog ports and two bundles activated at the same time The status is indicated with a message OFF if you create a new bundle in the same position as one...

Page 37: ...port mode is server and is waiting for a client connection When the Terminal Server Port is connected with a remote the Remote IP is in green when it is not connected the color is red 5 3 20 Logger M...

Page 38: ...Save Save a configuration file from CIP ALL to a Computer Factory reset Restore factory settings of the CIP ALL 5 3 22 Password This page allows you to change the password to access the CIP ALL Enter...

Page 39: ...You can then complete the FTP session close or quit command It is usually required to update both units of a link you should then update the remote CIP ALL first Then open a second FTP session to upg...

Page 40: ...ion 108 3 dB max FXO port 2 wires to connect a PBX FXS port 2 wires to connect a telephone Port EM 2 or 4 audio wires Bandwidth 300 to 3400 Hz input 0 dB max 4 wires E M type E M SG SB 6 2 General Cha...

Page 41: ...must have the serial number of the device 13 digits Then you contact the CXR support support cxr fr or by phone you give the serial number and you obtain the new password for the unit Login CXR Passwo...

Page 42: ...OPT_FRAMER 0 STATUS MEMFREE 93292kB SYSCFG_DISK 204 0K 576 0K UPTIME 34min root CIP ALL root system status switch Port Link STP TX RX 0 LAN1 UP 100MBPS HDX FORWARDING 31312641 15976369 1 LAN2 DOWN 10...

Page 43: ...D In Data transmit by the Terminal 3 7 106 CTS Out CIP ALL ready to use 8 8 105 RTS In Terminal ready to Send Common Relay 7 An RJ45 to DB9 adapter ref 7055 031 517 is provided to connect to the DB9 s...

Page 44: ...ough CIP ALL over the IP network RS 232 serial Port PIN Signal I O Description DB9 1 107 DSR Out Modem ready always ON 6 2 109 CD Out Modem connected always ON 1 3 108 DTR In Terminal ready 4 4 102 GN...

Page 45: ...t Tip audio output 6 T1 In Tip 1 audio input 7 8 Mode 8 wires analog E M interface Pin Analog In Out Description 1 SB In Out Signal Battery 2 M In out Mouth 3 R1 In Ring 1 audio input 4 R Out Ring aud...

Page 46: ...your eyes 8 1 5 10 100Base TX RJ45 LAN Port Four RJ45 sockets connect to the LAN or to Ethernet equipment A category 5 cable should be used to connect the unit to a switch a hub or the terminal equip...

Page 47: ...bel will render the RJ 45 E1 interfaces inoperative but will activate the 75 ohm coaxial connectors In that case the left BNC is the transmit pair and the right one is the receive pair of the E1 75 Oh...

Page 48: ...1 SB In Out Signal Battery SB switch with M 2 M In Out M switch with SB 7 E In E Detector connected to 48Volts 8 SG Out Signal Ground 0 Volts Type B2 Pin Analog Input Output Description 1 SB Out Sign...

Page 49: ...gnal M Interrupteur vers la Masse 7 E In Signal E D tecteur reli au 48Volts 8 SG Out Signal Ground Masse 0 Volts CXR Type B5 Pin Analog Input Output Description 1 SB Not connected 2 M In Signal M Dete...

Page 50: ...Magneto or Ear and Mouth On a side we have a voltage 48 Volts or not 0V on the other side we have a current detector Actual type between Exchange Side A PBX and a Carrier Side B The PBX side A must be...

Page 51: ...to the ground signal M is connected to the internal relay A CIP configured in type 5 side B signal M is connected to the detector and detector is connected to the 48Vdc Signal E is connected to the in...

Page 52: ...Vdc 5 only when EM card is present Optionally connect the device to frame ground GND CIP ALL C2 Connect one or two 12 24Vdc sources Respect the polarity Optionally connect the device to frame ground G...

Page 53: ...ling screws on both brackets 8 2 2 Wall or panel mounting Optional with WALL 1CIP accessories two small brackets can be fixed CIP ALL equipment on a wall or support On the right side dismantle the exi...