![CXR CIP-2ALL User Manual Download Page 51](http://html1.mh-extra.com/html/cxr/cip-2all/cip-2all_user-manual_2701290051.webp)
User manual
CIP-ALL
CIP-ALL
- Page 51
E&M card with Jumpers J1 for E&M configuration.
Jumpers A to G define the type and side of the E&M interface.
The default configuration is B5, identified with a sticker.
A CIP configured in type 5, side A: signal E is connected to the detector and detector is connected to the ground, signal M is connected to the
internal relay.
A CIP configured in type 5, side B: signal M is connected to the detector and detector is connected to the -48Vdc, Signal E is connected to the
internal relay.
Jumpers
Side,
Type
A
B
C
D
E
F
G
A – 1
2-3
2-3
2-3
2-3
1-2
A – 2
1-2
1-2
2-3
2-3
1-2
A – 3
1-2
2-3
2-3
2-3
1-2
A – 4
1-2
1-2
2-3
2-3
1-2
A – 5
1-2
2-3
1-2
2-3
2-3
1-2
B – 1
1-2
2-3
1-2
1-2
2-3
B – 2
2-3
2-3
2-3
1-2
1-2
2-3
B – 3
1-2
2-3
1-2
1-2
1-2
2-3
B – 4
2-3
1-2
2-3
2-3
1-2
2-3
B – 5
1-2
1-2
2-3
1-2
2-3