CAUTION
NEVER FILL BATTERY IN MACHINE AS SPILLS WILL DAMAGE FINISH AND CAUSE
PREMATURE CORROSION AND/OR DAMAGE TO COMPONENTS
.
D. Charge 12 volt battery at 3 - 4 amps until the acid temperature is above 80°F
(26 °C), and the hydrometer reading is 1.250 or higher. Acid temperature
must never exceed 125 °F while charging.
NOTE
: Both temperature and hydrometer readings must be met.
E. After charging the battery, check acid levels in all cells and f
i
ll each cell with
acid to the proper level.
F
.
Re-install vented caps.
G. Re-install the battery onto the machine in same position as it was before being
H. Connect the RED positive (+) cable to the positive terminal of the battery and
fasten it securely with the hardware provided.
I. Connect the BLACK negative (-) cable to the negative terminal of the battery
and fasten it securely with the hardware provided.
CAUTION
i
When installing the battery, connect the negative (-) cable last
to prevent sparking and shorting.
i
When disconnecting is required, remove the negative (-) cable
first.
i
Reverse polarity can cause damage to the starting and
charging system.
After battery has been initially service, only water should be added to restore the
liquid level in each cell. Further addition of acid will cause battery failure.
7
11
Summary of Contents for 2742
Page 53: ...ENGINE WIRING DIAGRAM 53 ...
Page 54: ...REMOTE CONTROL BOX SCHEMATIC 54 ...
Page 55: ...55 PUMP AND CONTROL SCHEMATICS ...
Page 56: ...56 POWER REGULATOR SCHEMATICS ...
Page 57: ...57 MOTOR CONTROL SCHEMATICS ...
Page 58: ...58 TACHOMETER DECODE SCHEMATICS ...
Page 59: ...59 SPEED DECODE SCHEMATICS ...
Page 60: ...4 MPH SWITCH SCHEMATICS 60 ...
Page 62: ...62 ...
Page 63: ...63 ...
Page 64: ...64 ...
Page 65: ...CURTIS DYNA FOG Ltd WESTFIELD INDIANA U S A MAXI PRO TM 4 MODEL 2742 SERIES 5 65 ...
Page 71: ...71 ...
Page 73: ...73 ...
Page 77: ...SAMPLE CONNECTIONS USING STEEL PLASTIC GRIPPER NUT 48 77 ...
Page 78: ...78 ...
Page 79: ...79 ...