MOTOR CONTROL MODULE
The motor control module receives a command from the rate potentiometer
located on the remote control box and generates a variable pulse width
command to the formulation motor. The command signal is added to the feed
back signal generated by the tachometer decode circuit and a difference
amplified drives the variable pulse width generator.
This module also contains the circuits needed to operate the fault indicator in
the remote control box and to provide the voltage to open the 3-way solenoid
valve. Pin outs for the motor control module are as follows:
PIN FUNCTION
DESCRIPTION
1 System ground in
Provides ground to module from system
2 Rate command
Command voltage from potentiometer in remote control
box.
Ground to voltage regulator.
+5.00+/-.12VDC.
Ground to remote control box.
3 Ground
4
+5 V DC
5 Ground
FAULT OUT
OUT TO LOW OVERRANGE
GROUND TO TAC & SPEED
COMPOSITE FAULT INPUT
CONTROL ON COMMAND
RATE FEEDBACK
+ 5 VDC INPUT
RATE COMMAND
NOT USED
+12 VDC INPUT
NOT USED
LOW RATE IN
LOW RATE OUT
GROUND TO REMOTE
GROUNG TO REG.
SYSTEM GROUND IN
REFERENCE TAB
45
Summary of Contents for 2742
Page 53: ...ENGINE WIRING DIAGRAM 53 ...
Page 54: ...REMOTE CONTROL BOX SCHEMATIC 54 ...
Page 55: ...55 PUMP AND CONTROL SCHEMATICS ...
Page 56: ...56 POWER REGULATOR SCHEMATICS ...
Page 57: ...57 MOTOR CONTROL SCHEMATICS ...
Page 58: ...58 TACHOMETER DECODE SCHEMATICS ...
Page 59: ...59 SPEED DECODE SCHEMATICS ...
Page 60: ...4 MPH SWITCH SCHEMATICS 60 ...
Page 62: ...62 ...
Page 63: ...63 ...
Page 64: ...64 ...
Page 65: ...CURTIS DYNA FOG Ltd WESTFIELD INDIANA U S A MAXI PRO TM 4 MODEL 2742 SERIES 5 65 ...
Page 71: ...71 ...
Page 73: ...73 ...
Page 77: ...SAMPLE CONNECTIONS USING STEEL PLASTIC GRIPPER NUT 48 77 ...
Page 78: ...78 ...
Page 79: ...79 ...