BY PASSING THE AIR PRESSURE SWITCH
PUMP AND CONTROL ASSEMBLY, P/N 64617-R
(RELATIVE LOCATION OF PRESSURE SWITCH)
The air pressure switch is part of the logic of the circuit, allowing the operation of the
formulation pump only if the air nozzle boom pressure is present. With this feature the machine
is not able to pump (spill) the formulation with the engine/blower off (stopped).
Bypassing the pressure switch will enable you (without the machine’s engine running) to
determine if the switch is functioning properly.
To bypass the pressure switch located inside the formulation pump enclosure perform the
following:
1. Remove the orange wire from the terminal “NO3” (normally opened), and remove the piece
of tubing from terminal “NC2” (normally closed). Place the orange wire onto terminal “NC2”.
Doing this will enable the formulation pump to be operated without the machine’s engine
running.
2. Replace orange wire and tubing back into their original positions when finished.
COM
RED WIRE
NO3
AIR PRESSURE
FROM BLOWER
NC2
PIECE OF TUBING
ORANGE
WIRE
PRESSURE SWITCH
61
Summary of Contents for 2742
Page 53: ...ENGINE WIRING DIAGRAM 53 ...
Page 54: ...REMOTE CONTROL BOX SCHEMATIC 54 ...
Page 55: ...55 PUMP AND CONTROL SCHEMATICS ...
Page 56: ...56 POWER REGULATOR SCHEMATICS ...
Page 57: ...57 MOTOR CONTROL SCHEMATICS ...
Page 58: ...58 TACHOMETER DECODE SCHEMATICS ...
Page 59: ...59 SPEED DECODE SCHEMATICS ...
Page 60: ...4 MPH SWITCH SCHEMATICS 60 ...
Page 62: ...62 ...
Page 63: ...63 ...
Page 64: ...64 ...
Page 65: ...CURTIS DYNA FOG Ltd WESTFIELD INDIANA U S A MAXI PRO TM 4 MODEL 2742 SERIES 5 65 ...
Page 71: ...71 ...
Page 73: ...73 ...
Page 77: ...SAMPLE CONNECTIONS USING STEEL PLASTIC GRIPPER NUT 48 77 ...
Page 78: ...78 ...
Page 79: ...79 ...