Expert-50 rev.10
Expert-50
Adjusting First and Fully Opened Tunnel Stages
Fan stages 1 and 2 cannot be tunnel stages. The first and fully opened
tunnel stages must be equal or in increasing order. Note all fan stages
above the first tunnel stage are considered tunnel stages.
Set the function to
SETTINGS –
OUTPUTS
using the menu select but-
tons. The start and stop tempera-
tures for Heater 8 are displayed and
the Heater 8 LED on the right flashes.
Use the output select buttons to select
TUNNEL CURTAIN – OPEN
.
The corresponding LED on the right of the front panel flashes.
Press Edit key. The first tunnel stage flashes. Use the arrow keys
to adjust the first tunnel stage to the desired value.
Press Edit key. The fully opened tunnel stage flashes. Use the
arrow keys to adjust the fully opened tunnel stage to the desired
value.
Adjusting Minimum Age
The minimum age is used to prevent tunnel ventilation from being used
when the animals are too young. The value ranges from 1 to 250 days.
The tunnel stages do not operate until the herd age reaches this value.
Set the function to
SETTINGS – OUTPUTS
using the menu select
buttons. The start and stop temperatures for Heater 8 are displayed
and the Heater 8 LED on the right flashes.
Use the output select buttons to select
TUNNEL CURTAIN – OPEN
.
The corresponding LED on the right of the front panel flashes.
Press the down-arrow key to
display the minimum age.
Press the Edit key. The minimum age value flashes on the display. Use
the arrow keys to adjust the minimum age to the desired value.
First stage: 9
100% opened: 12
Minimum age: 20