13
Expert-50 rev.10
Expert-50
RH influence on
min. vent.? YES
RH influence on
Cooling? YES
Use humidity
sensor (RH)? YES
Use water
meter? YES
Temperature
units: °F
Fan Start-Stop
T° diff: 1.5°F
4. Use Humidity Sensor:
Press the
Edit key and set to YES if a relative
humidity sensor is connected to the
unit.
5. Use Water Meter:
Press the Edit
key and set to YES if a water meter is
connected to the unit.
6. Temperature Units:
Press the Edit
key and choose between Fahrenheit
and Celsius degrees for displaying
temperature values.
7. Fan Start-Stop Temperature
Difference:
Press the Edit key and
adjust the maximum temperature
difference between start and stop
temperatures on fan stages.
8. Variable-Speed Fan Minimum
Speeds:
Press the Edit key and adjust
the minimum speed for the first
variable output. Repeat for the second
variable output.
9. Humidity Compensation on Mini-
mum Ventilation:
Press the Edit key
and set to YES to enable humidity
compensation on the minimum ventila-
tion cycle.
10. Humidity Compensation on
Heating:
Press the Edit key and set to
YES to enable humidity compensation
on heating.
11. Humidity Compensation on
Cooling Stages:
Press the Edit key
and set to YES to enable humidity
compensation on cooling outputs.
V1 Min. spd: 10 %
V2 Min. spd: 10 %
RH influence on
Heating ? YES