25
Expert-50 rev.10
Either variable outputs or both can be used for minimum ventilation.
Minimum ventilation fan speed can also be controlled over time using a
curve (see below).
Note that the minimum ventilation curve must be turned off to
adjust the minimum ventilation settings.
Adjusting Minimum Speeds
The minimum speed must be adjusted on both variable outputs used for
minimum ventilation. To deactivate minimum ventilation on an output,
set the minimum speed to OFF.
Set the function to
MINIMUM
VENTILATION/CURVE
using
the menu select buttons. The
current minimum speeds for
the variable outputs are displayed, as well as the on-off state of the
minimum ventilation curve.
If the curve is ON
, press the Edit key. The on-off state of the curve
flashes on the display. Use the arrow keys to turn the curve OFF.
Press the Edit key once again and follow the instructions below.
ON
OFF
ON TIME
TIMER CYCLE
MINIMUM VENTILATION
PRINCIPLE OF OPERATION
When the room temperature is below the set point,the variable-speed
fans can operate according to a minimum ventilation cycle. Running the
fans even though ventilation is not required for reducing room tempera-
ture is useful to reduce humidity levels and supply oxygen to the room.
It also prevents the fans from freezing in winter.
V1 10% curve OFF
V2 10%