Adjusting Low and High Alarm Temperatures
The low alarm temperature can be adjusted from 40°F to 0.5°F below the
set point. The high alarm temperature can be adjusted from 0.5°F to
60°F above the set point. A change in the set point will change these
values by the same amount.
Set the function to
SETTINGS – OUTPUTS
using the menu select
buttons. The start and stop temperatures for Heater 8 are displayed
and the Heater 8 LED on the right flashes.
Use the
output select buttons
to select
ALARM
. The corresponding
LED on the right of the front panel flashes.
Press Edit key. The low alarm tem-
perature value flashes. Use the ar-
row keys to adjust the low alarm
temperature to the desired value.
Press Edit key. The high alarm temperature value flashes. Use the
arrow keys to adjust the high alarm temperature to the
desired value.
Low: 74.5°F
High: 95.0°F