23
Expert-50 rev.10
Expert-50
Viewing Current Set Point and Day Number
When the temperature curve is activated, the current temperature set
point and day number can be viewed at any time. The current day
number can also be adjusted in order to move forward or backward on
the temperature curve.
Note that the day number used by the curve is defined by the herd
age value which is also used by the minimum ventilation curve.
Set the function to
ROOM SET POINT /
CURVE
using the menu
select buttons. The current temperature set point is displayed, as
well as the on/off state of the temperature curve.
Set the function to
AGE
using the menu select buttons. The current
herd age is displayed.
Press the Edit key. The age value flashes on the display.
Use the arrow keys to set the age to the desired value.
Summary of Contents for EXPERT-50
Page 1: ...Expert 50 Temperature Controller USER S MANUAL M 890 00075 rev 10 REV 01...
Page 2: ......
Page 57: ...NOTES NOTES...