42
Expert-32P rev.11
Expert-32P
1
Adjusting Cooling Start and Stop Temperatures
Start temperatures must be greater than the set point.
Set the function to
START / STOP TEMPERATURE
using the menu
select buttons. The start and stop temperatures for Heater 8 are
displayed and the Heater 8 LED on the right flashes.
Use the output select buttons to
select the cooling stage to adjust.
The corresponding LED on the
right of the front panel flashes.
Press Edit key. The start tempera-
ture flashes. Use the arrow keys to adjust the start temperature to
the desired value.
Press Edit key. The stop temperature flashes. Use the arrow keys to
adjust the stop temperature to the desired value.
2
Adjusting Cooling Timer Settings
On and off times range from 0 minutes, 0 seconds to 99 minutes, 59
seconds.
Follow the procedure above to select the cooling stage to adjust.
Press the down-arrow key to
display the timer settings.
Press the Edit key. The on time minutes value flashes on the display.
Use the arrow keys to adjust the minutes to the desired value.
Press the Edit key. The on time seconds value flashes on the display.
Use the arrow keys to adjust the seconds to the desired value.
ON time: 1m00
OFF time: 2m00
Start: 61.0°F
Stop: 60.0°F
Summary of Contents for Expert-32P
Page 1: ...Expert 32P Temperature Controller USER S MANUAL...
Page 7: ...7 Expert 32P rev 11 LOCATION OF THE CONTROLS...
Page 74: ......
Page 75: ......
Page 76: ...REV 01 M 890 00073 rev 11...