21
Expert-32P rev.11
TEMPERATURE SETTINGS
VIEWING TEMPERATURES
The user can display the current average room temperature and indi-
vidual probe temperatures. The controller also records the minimum and
maximum temperature values for the current day and the past 6 days
along with the clock time. The controller starts recording minimum and
maximum values at midnight every day.
The controller uses two probe sets to determine the average room
temperature. The currently active fan stage determines which probe set
is used (see "Fan Settings"). Note that when all the probes in a set are
defective, the controller operates with the other set.
1
Viewing Room Temperature
The room temperature is the average value of all temperatures mea-
sured by selected probes in proper operating condition.
Set the function to
ROOM
TEMPERATURE
using the menu se-
lect buttons. The average room tem-
perature is displayed. The probes se-
lected for calculating room tem-
perature flash on the display.
Press the down-arrow key. The
minimum temperature value for the
current day is displayed, along with
the time and date.
Press the down-arrow key once again. The maximum temperature
value for the current day is displayed, along with the time and date.
Keep pressing the down-arrow key to display the minimum and maxi-
mum temperature values for the previous six days. Use the up-arrow
key to return to the previous display screens.
Room 01/02/99
min 42.1 09:06A
Room 76.5 °F
Probes: 123456
Summary of Contents for Expert-32P
Page 1: ...Expert 32P Temperature Controller USER S MANUAL...
Page 7: ...7 Expert 32P rev 11 LOCATION OF THE CONTROLS...
Page 74: ......
Page 75: ......
Page 76: ...REV 01 M 890 00073 rev 11...