Part No. 4801-5331 Rev 2-2015
Evolution 1200
23 of 65
(1)MODULES (2)ENABLED (3)STATUS
EV-INPUT/OUTPUT Yes
OK
EV-16(1-16) or SCS-16 Yes
OK
EV-16(17-32) or SCS-8 Yes
OK
EV-16(33-48) No
OK
EV-16(49-64) No
OK
BACK-UP/S3 Yes
OK
HEAT ZONE No
OK
6.8
Network Status
The Network Status shows the installed Evolution Stages, the Back-Up and the Heat Zone. The ENABLED
indicator shows if the stage is enabled and the STATUS indicates OK or Failed.
(1) Modules –
The Evolution modules that can be installed will appear here. EV I/O - This is the back
board of the Evolution 1200.
(2) Enabled –
Those modules that are enabled will be indicated by Yes. This column lets you know which
modules are turned on for the Evolution control to communicate with. When adding expansion back-up
modules, the ENABLED must be set to “Yes” for proper operation.
(3) Status -
OK or Failed. This column lets you know if you have lost communication with one of the
modules.
6.9
Program Set-Up
The Program Setup screen is used to select all of the Programming screens. Highlight an entry and press
the ENTER button. See the next section of this manual for a description of the programming screen.
(1) General Settings –
Parameters that usually need to
be set when the system is installed. See
Section 7.1
(2) Temperature Sensors –
See
Section 7.2
(3) Feed Level Sensors -
See
Section 7.3
(4) Ventilation Inlets -
See
Section 7.4
(5) Natural Ventilation -
See
Section 7.5
(6) Growout Curve -
See
Section 7.6
(7) Tunnel Ventilation -
See
Section 7.7
(8)-(11) On/Off Stages -
Settings for Set up of stages.
See
Section 7.8
(12) Variable Stage Outputs -
Set-up for variable
stages. See
Section 7.9
(13) Stage Properties –
See
Section 7.10
(14) Setup Feed Clocks –
See
Section 7.11
(15) Setup Light Clocks -
This feature is added for
those applications that desire light control See
Section 7.12
(16) Seasonal Programs & Password Setup –
See
Section 7.13
(17) Diagnostics -
See
Section 7.14
1. General Settings
2. Temperature Sensors
3. Feed Level Sensors
4. Ventilation Inlets
5. Natural Ventilation
6. Growout Curve
7. Tunnel Ventilation
8. On/Off Stages 1-16
9. On/Off Stages 17-32
10. On/Off Stages 33-48
11. On/Off Stages 49-64
12. Variable Stage Outputs
13. Stage Properties
14. Setup Feed Clocks
15. Setup Light Clocks
16. Seasonal Programs & Password Setup