5.5
Status Display
The following is an example of Main Display screen displaying the standard Target Conditions status
screen. The Main Display screen displays both status and programming screens.
5.6
Stage Switch
The stage LED indicator lights when a stage is active. The stage switch is used to select Auto operation,
On, or Off. If switch is in Auto position, the stage operation is controlled by the controller. That is, the
stage may turn on and off according to settings selected from the Main Display screen. If switch is in the
On position, a stage is On continuously. If switch is in the Off position, a stage is Off with the exception of
Back-Up conditions.
The white space is used to affix a Stage Description label indicating stage function (i.e. brooder, fan, light,
cool, etc.).
NOTE: Stages 1 thru 8 are marked on the front panel. For optional Variable Stages 7 & 8, use stick-on
V1/V2 label placed over stages 7 & 8 numbers.
Stage number
(Use V1-V2 label over
Stages 7 & 8 if Stages 7
& 8 are used for
Variable Output).
AUTO, OFF, ON
Switch positions
Stick Stage
Description label onto
white area or use for
notation.
LED Indicator (lights
when stage is ON)
Stage Description labels
are provided to affix to
white area of stage
control. Stage
Description labels are
shown at right.
The Scroll Symbol is a
flashing down arrow (
) that
indicates more text outside
of display screen. Use
up/down editor arrow keys
to scroll text.
The Link Symbol (
) is a right
pointing arrow and indicates a
link to another display screen.
To change
parameter:
Select parameter
using editor
arrow keys. Use
+ and - keys to
change value.
(1)Target Temp =
77.5°
(2)Ramping:
On
(3)Target Press =
0.04 wc
(4)Ramping:
Off
(5)Tunnel Press =
0.00 wc
(6)Target Humidity < 60%
(7)Light Schedule
(8)Feed
Schedule
77.5°
NOTE: If Optimum Mode is turned On, the Target Conditions screen