Part No. 4801-5331 Rev 2-2015
Evolution 1200
51 of 65
8.12 Connecting PowerTrak Natural Auxiliary Switches to Evolution 1200
PowerTrak
AUX
SWITCH
CONTROLLER
AC IN
HO
T
NE
UT
.
LOW
E
R
GN
D.
HO
T
OU
T
CLOS
E
IN
OP
E
N
IN
CO
M
UP
P
E
R
NOTE: If curtain is setup to pull curtain up to open, then reverse wires
connected to 'Upper' and 'Lower' terminals.
Inset B
Inset A
Natural Auxiliary
Input
Close
Aux.
Close
Aux.
Com .
Com .
Auxiliary Inputs
WARNING!
LOW VOLTAGE!
Keep Separate From
High Voltage Wires!
Inset B
PCB 186
Inset A