Part No. 4801-5331 Rev 2-2015
Evolution 1200
16 of 65
Select and Press ‘Enter’:
Room Temperature
Stage 1 – 16 RunTimes
Humidity
Stage 17 – 32 RunTimes
Water Usage #1
Stage 33 - 48 RunTimes
Water Usage #2
Stage 49 – 64 RunTimes
Ventilation Mode
PowerTrack RunTimes
Feed History
Alarm Log
(1)# (2)STATUS
(3)MODE
(4)RTEMP (5)ON (6)OFF (7)TIME
.
.
.
.
.
.
.
V1
50%
Light
Ramp
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
V2
75%
CStir
88.7°
76.4° 74.0°
None
Min1
.
.
.
.
.
.
.
.
.
.
.
.
.
.
(1)DAY (2)HIGH TEMP (3)AVE (4)LOW TEMP
21
71.0°-12:34p
66.3°
61.6°–12:34a
20
71.0°-12:34p
66.3°
61.6°–12:34a
.
. .
.
. .
.
. .
.
. .
1
71.0°-12:34p
66.3°
61.6°–12:34a
6.4.4 Variable Stages
The Variable stages are used to control devices (i.e. fans & lights) with a variable capability. The same V1
& V2 settings shown in this screen are also shown in the top portion of the Onboard On/Off Stages screen.
(1) # -
The Stage bank either V1 or V2.
(2) Status -
This is the current run percentage that the device is operating.
(3) Mode –
Indicates how the stage is programmed: CSTIR, CNEG, CNEGT, CTUN or LIGHT.
(4) Rtemp
–The Rtemp column indicates the current temperature from which the stage is operating.
(5) ON –
The ON column indicates the maximum ON temperature at which the variable speed fan will reach
full speed.
(6) OFF -
The OFF column indicates the minimum ON temperature at which the fan will run at minimum
speed.
(7) Time –
None, Min1, Min2, Var or Always ON (ON). Always ON when Rtemp is below MIN ON.
6.5
Historical Data
This screen provides access to historical data. Highlight the selection and press the ENTER button on the
EDITOR panel.
NOTE: The Historical Data for Onboard Stages 1 thru 8 will be found in “Stage 1-16 Runtimes”.
6.5.1 Room Temperature
This screen shows the highest and lowest
room temperature for each day for up to 99
days. The last day reported will appear at the
top of the list. The list can contain data up
to 99 days. After displaying 99 days, oldest
data will be deleted.
(1) Day –
The specific day in the growout
period. Values = 1 day to 99 days.
(2) High Temp
– The high recorded temperature and the time of day that it occurred.
(3) AVE
– The average recorded temperature for the day.
(4) Low Temp -
The low recorded temperature and the time of day low temperature occurred.
NOTE: The High and Low temperature readings are taken from the Sensors for Display in "Sensor Setup"
of the Program Setup Screen.