Part No. 4801-5331 Rev 2-2015
Evolution 1200
10 of 65
** PASSWORD PROTECTED **
You must enter the current controller
Password to continue.
Press the ENTER button to proceed.
Password: XXXX
NOTE: In this manual, Reference
numbers refer to descriptions given in
text. These numbers do not appear
on display.
Mon 14 Jun 2007 5:00 p
(1) Vent Mode: Minimum (6) Growout Day: 40
(2) Room Temp: 71.4°
(7) Water Consumption
Target: 70.0°
1. 240 (10/hr)
(3) Outside: 77.0°
2. 280 (10/hr)
(4) Pressure: 0.00 wc (8) Feed Levels
Target: 0.04 wc 1. 11.2ft ( 60%)
(5) Humidity: 0%
2. 5.0ft ( 23%)
(9)
* Sensor 1: 71.6°
* Sensor 2: 71.2°
* Sensor 3: 71.4°
Sensor 4:---.-°
Sensor 5:---.-°
Sensor 6:---.-°
Sensor 7:---.-°
Sensor 8:---.-°
Sensor is enabled
* Sensor used in Room Temp Calculation
5.7
Locks
A lock feature is included for additional security to
the Evolution 1200 settings. This feature locks the
Program Setup screens to prevent changes. Locked
screens are noted by a lock symbol ( ) in the
upper right of the screen. The Target Conditions
and Minimum Vent screens are not lockable. When
the lock feature is disabled ( ), all screens will
show unlocked until the password is changed. See
Section 7.13.
NOTE: The Diagnostics screen can only be unlocked using the HHI Service Code; Contact your local
dealer for assistance.
6. Viewing Navigator Status Screens
The following nine screens are available: Current Conditions, Target Conditions, Minimum Vent, Stage
Conditions, Historical Data, Back-Up Status, Alarm Status, Network Status, Program Setup. The Navigator
selects the desired status screen by pressing the up and down SELECT arrows. The first eight screens
display status information and various setup options. The last screen is the Program Screen. To change
program parameters the Program Setup Screen must be selected.
6.1
Current Conditions
The current environmental conditions of the building are shown here. Below is a table describing the
variables that can appear in the Current Conditions status screen.
The numbers in brackets e.g. (1) refer to the descriptions below the sample screen displays.
(1) Vent Mode –
Indicates the current ventilation mode: either Minimum, Natural, Power, Transition or
Tunnel.
(2) Room Temp –
The average temperature of the sensors for display.
Target-–
Target Temperature.
(3) Outside (Temperature) –
The outside temperature as indicated by the outside sensor.
(4) Pressure –
The current atmospheric pressure internal to the building.
Target-–
Target Pressure.
(5) Humidity –
The percent of water vapor of the air inside the building.